Effects of Graded Lower-Extremity Compression Pressure on Peripheral Photoplethysmographic Responses After Surgery: A Pilot Repeated-Measures Study
Life · 16.11.2026 · 16 (11) · 1938
DOI: 10.3390/life16111938 ↗Kurz gefasst
Fachartikel in der Zeitschrift Life, online erschienen am 16.11.2026. Verfasst von Volkan Gökmen und 5 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Postoperative calf compression is widely used, but the relationship among acute pressure-dependent optical responses, patient tolerability, and safety remains uncertain. This prospective, single-center methodological–physiological pilot study (ClinicalTrials.gov NCT07394829) included 30 postoperative adults who underwent sustained calf compression at 30, 45, and 60 mmHg in randomized, counterbalanced sequences. Outcomes included peripheral perfusion index (PPI), an exploratory post-compression photoplethysmographic (PPG) amplitude-recovery descriptor, discomfort, autonomic and hemodynamic indices, and adverse events. Mean PPI increased from 1.79 ± 0.32 to 2.01 ± 0.34 and 2.18 ± 0.34, whereas 90 threshold PPG recovery time decreased from 14.20 ± 3.18 to 12.20 ± 3.17 and 11.17 ± 3.25 s across the three pressures (both overall p < 0.001). Alternative recovery thresholds showed the same pressure-related ordering. Median discomfort increased from 1 to 3 and 4; five moderate, self-limited events occurred in four participants, including four events at 60 mmHg. Exploratory comparisons of surgical groups did not demonstrate clear pressure-by-group interaction. Increasing pressure was associated with greater optical responses but also greater discomfort. The 90% recovery criterion is operational, not clinically validated; neither this descriptor nor PPI establishes improved tissue perfusion or postoperative benefit. The main contribution is preliminary methodological characterization and feasibility assessment to inform future validation studies.
Zitieren
APA
Gökmen, V., Yılmaz, D. A., Kajti, E., Aslan, A., Gökmen, B. D., & Okucu, F. (2026). Effects of Graded Lower-Extremity Compression Pressure on Peripheral Photoplethysmographic Responses After Surgery: A Pilot Repeated-Measures Study. Life, 16(11), 1938. https://doi.org/10.3390/life16111938
Vancouver
Gökmen V, Yılmaz DA, Kajti E, Aslan A, Gökmen BD, Okucu F. Effects of Graded Lower-Extremity Compression Pressure on Peripheral Photoplethysmographic Responses After Surgery: A Pilot Repeated-Measures Study. Life. 2026;16(11):1938. doi:10.3390/life16111938
BibTeX
@article{Gkmen2026,
author = {Gökmen, Volkan and Yılmaz, Dursun Alper and Kajti, Eva and Aslan, Adem and Gökmen, Burcu Demir and Okucu, Fatma},
title = {Effects of Graded Lower-Extremity Compression Pressure on Peripheral Photoplethysmographic Responses After Surgery: A Pilot Repeated-Measures Study},
journal = {Life},
year = {2026},
volume = {16},
number = {11},
pages = {1938},
doi = {10.3390/life16111938}
}
EUVIMED