EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Short-Term Impact of Scleral Lens Wear on Intraocular Pressure and Retinal Nerve Fiber Layer Thickness

Pabita Dhungel iD, Muteb K Alanazi, Patrick Caroline, Lorne Yudcovitch iD, Maria Liu

Life · 30.06.2026 · 16 (7) · 1094

DOI: 10.3390/life16071094 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Life, online erschienen am 30.06.2026. Verfasst von Pabita Dhungel und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Optometry, University of California, Berkeley, CA 94720, USA. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the short-term impact of scleral lens wear on intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) thickness. We hypothesized that scleral lens wear would produce a measurable elevation in IOP accompanied by detectable RNFL thinning compared with soft contact lens wear.

Methods

This prospective, randomized, contralateral-eye crossover study included 31 healthy participants (mean age: 26 ± 3 years). Each participant wore a 16.5 mm scleral lens over one eye and a soft contact lens over the fellow eye for 8 h, with assignments reversed between visits. IOP was measured using two tonometers: a transpalpebral Diaton tonometer and a non-contact tonometer (NCT), and RNFL thickness was measured by optical coherence tomography at four time points: pre- and post-lens application, and pre- and post-lens removal.

Results

Eyes fitted with scleral lenses exhibited a significant IOP increase immediately after lens application (pre-application: 11 ± 3 mmHg vs. post-application: 16 ± 4 mmHg, p < 0.001), sustained throughout 8 h of wear (pre-removal: 16 ± 4 mmHg), and returned to baseline after removal (11 ± 3 mmHg). No significant IOP changes were observed in soft contact lens-wearing eyes (p > 0.05). Scleral lens wear was also associated with small but statistically significant peripapillary RNFL thinning (pre-application: 110 ± 11 µm vs. post-application: 107 ± 11 µm, p < 0.001), which returned to baseline after lens removal. No significant RNFL changes were observed with soft contact lens wear (p > 0.05). Bland–Altman analysis revealed poor agreement between Diaton and NCT measurements, consistent with the published literature on transpalpebral tonometry.

Conclusions

Short-term scleral lens wear was associated with transient IOP elevation and peripapillary RNFL thinning, both reversible upon lens removal, in healthy young adults. These findings highlight the need for further longitudinal investigation in at-risk populations such as those with ocular hypertension, keratoconus, or early glaucoma before clinical monitoring recommendations can be established.

Schlagwörter

Stichwörter der Autor:innen

contact lensintraocular pressureretinal fiber thicknessscleral lens

Autor:innen und Institutionen

  • School of Optometry, University of California, Berkeley, CA 94720, USA.
  • Optometry Department, College of Applied Medical Sciences, King Saud University, Riyadh 11362, Saudi Arabia.
  • College of Optometry, Pacific University, Forest Grove, OR 97116, USA.

ORCID-Profile: Pabita Dhungel, Lorne Yudcovitch

Zitieren

APA

Dhungel, P., Alanazi, M. K., Caroline, P., Yudcovitch, L., & Liu, M. (2026). Short-Term Impact of Scleral Lens Wear on Intraocular Pressure and Retinal Nerve Fiber Layer Thickness. Life, 16(7), 1094. https://doi.org/10.3390/life16071094

Vancouver

Dhungel P, Alanazi MK, Caroline P, Yudcovitch L, Liu M. Short-Term Impact of Scleral Lens Wear on Intraocular Pressure and Retinal Nerve Fiber Layer Thickness. Life. 2026;16(7):1094. doi:10.3390/life16071094

BibTeX
@article{Dhungel2026,
  author = {Dhungel, Pabita and Alanazi, Muteb K and Caroline, Patrick and Yudcovitch, Lorne and Liu, Maria},
  title = {Short-Term Impact of Scleral Lens Wear on Intraocular Pressure and Retinal Nerve Fiber Layer Thickness},
  journal = {Life},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {1094},
  doi = {10.3390/life16071094}
}
Kostenlos starten →