Impact of Preoperative Ocular Hypotony on Refractive Predictability After Phacovitrectomy for Rhegmatogenous Retinal Detachment
Life · 16.06.2026 · 16 (6) · 1009
DOI: 10.3390/life16061009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Life, online erschienen am 16.06.2026. Verfasst von Ayana Kurobe und 7 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki 852-8501, Japan. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: Rhegmatogenous retinal detachment is a vision-threatening condition often treated with combined cataract surgery and vitrectomy, but accurate postoperative refractive prediction may be difficult when ocular anatomy is altered by preoperative hypotony. This retrospective comparative study evaluated the effect of preoperative ocular hypotony on refractive predictability and visual outcomes after combined phacovitrectomy for rhegmatogenous retinal detachment. Materials and Methods: Electronic medical records from Nagasaki University Hospital from 2010 to 2022 were reviewed. Among 731 eyes that underwent combined phacovitrectomy with sulfur hexafluoride gas tamponade for rhegmatogenous retinal detachment, 17 eyes with preoperative ocular hypotony (intraocular pressure ≤ 7 mmHg) that met the inclusion criteria were identified. Thirty-four eyes with normal intraocular pressure were selected as controls in a 1:2 ratio. Refractive outcomes were assessed through spherical equivalent and mean absolute error, and visual outcomes were evaluated through best-corrected visual acuity at baseline and 6 months postoperatively.
Results
Mean absolute error was significantly higher in eyes with hypotony than in normotonic eyes (1.46 ± 0.95 diopters vs. 0.70 ± 0.81 diopters; p = 0.002; mean difference, 0.76 D; 95% CI, 0.21–1.31; Hedges’ g = 0.87). Target postoperative refraction within ±0.5 diopters was achieved in 23.5% of hypotonic eyes and 50.0% of normotonic eyes (p = 0.07), the corresponding proportions within ±1.0 D were 35.3% and 76.5%, respectively (p = 0.006). Best-corrected visual acuity improved significantly in both groups, but final visual acuity at 6 months was worse in hypotonic eyes (0.35 ± 0.31 vs. 0.09 ± 0.17 logarithm of the minimum angle of resolution; p < 0.001).
Conclusions
Preoperative ocular hypotony in rhegmatogenous retinal detachment was associated with greater refractive prediction error and worse visual outcomes after phacovitrectomy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki 852-8501, Japan.
- Science Management Department, Kazakh Eye Research Institute, Almaty 050012, Kazakhstan.
- Department of Ophthalmology and Visual Sciences, Nagasaki University, Nagasaki 852-8501, Japan.
- Department of Postgraduate Education, Kazakhstan Medical University "Higher School of Public Health", Almaty 050060, Kazakhstan.
ORCID-Profile: Kairat Ruslanuly, Akira Machida, Akio Oishi
Zitieren
APA
Kurobe, A., Ruslanuly, K., Miyagi, S., Akiyama, F., Machida, A., Uematsu, M., Dautaliyeva, A., & Oishi, A. (2026). Impact of Preoperative Ocular Hypotony on Refractive Predictability After Phacovitrectomy for Rhegmatogenous Retinal Detachment. Life, 16(6), 1009. https://doi.org/10.3390/life16061009
Vancouver
Kurobe A, Ruslanuly K, Miyagi S, Akiyama F, Machida A, Uematsu M, et al. Impact of Preoperative Ocular Hypotony on Refractive Predictability After Phacovitrectomy for Rhegmatogenous Retinal Detachment. Life. 2026;16(6):1009. doi:10.3390/life16061009
BibTeX
@article{Kurobe2026,
author = {Kurobe, Ayana and Ruslanuly, Kairat and Miyagi, Sugao and Akiyama, Fumito and Machida, Akira and Uematsu, Masafumi and Dautaliyeva, Akbala and Oishi, Akio},
title = {Impact of Preoperative Ocular Hypotony on Refractive Predictability After Phacovitrectomy for Rhegmatogenous Retinal Detachment},
journal = {Life},
year = {2026},
volume = {16},
number = {6},
pages = {1009},
doi = {10.3390/life16061009}
}
EUVIMED