Maternal Salivary Glutamate Concentrations in Cesarean Delivery: A Prospective Comparison Between Spinal and General Anesthesia
Life · 01.05.2026 · 16 (5) · 748
DOI: 10.3390/life16050748 ↗Kurz gefasst
Fachartikel in der Zeitschrift Life, online erschienen am 01.05.2026. Verfasst von Diab Bani Hani und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia, Faculty of Medicine, Jordan University of Science and Technology, Irbid 21110, Jordan. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jordan University of Science and Technology, Deanship of Research, Jordan University of Science and Technology.
Abstract (Originalsprache)
Background
Cesarean delivery is commonly performed under either spinal or general anesthesia. While both techniques are widely used, their differential effects on maternal neurochemical profiles, particularly excitatory neurotransmitters such as glutamate, remain incompletely understood. Glutamate plays a central role in stress response, nociception, and neuroendocrine regulation. This study aimed to compare maternal salivary glutamate concentrations between spinal and general anesthesia during cesarean delivery.
Method
In this prospective study, 66 women undergoing cesarean delivery were included: 32 received spinal anesthesia and 34 received general anesthesia. Unstimulated saliva samples were collected perioperatively and analyzed using a colorimetric enzymatic assay. Clinical and demographic variables were extracted from electronic medical records.
Results
Baseline maternal and neonatal characteristics were comparable between groups (all p > 0.05). Glutamate concentrations were not normally distributed. Median salivary glutamate levels were significantly higher in the general anesthesia group compared with the spinal anesthesia group (8.05 nmol/µL [IQR 4.81–11.69] vs. 5.19 nmol/µL [IQR 3.05–8.39]; p = 0.041) After adjustment for maternal and perinatal covariates, anesthesia type was not independently associated with glutamate levels (p = 0.21).
Conclusion
General anesthesia was associated with higher unadjusted maternal salivary glutamate levels compared with spinal anesthesia during cesarean delivery; however, this association did not persist after multivariable adjustment. These findings suggest that anesthesia technique alone may not independently influence perioperative glutamatergic responses. Further research is warranted to clarify the clinical significance of these neurochemical changes for maternal and neonatal outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesia, Faculty of Medicine, Jordan University of Science and Technology, Irbid 21110, Jordan.
- Department of Obstetrics and Gynecology, Faculty of Medicine, Jordan University of Science and Technology, Irbid 21110, Jordan.
- Faculty of Medicine, Jordan University of Science and Technology, Irbid 21110, Jordan.
ORCID-Profile: Atef F Hulliel, Tala Ahmed
Förderung
- Jordan University of Science and Technology
- Deanship of Research, Jordan University of Science and Technology
Zitieren
APA
Bani Hani, D., Altal, O. F., Hulliel, A. F., Ahmed, T., Alrusan, A., Al Hazaymeh, M., Albusta, F., Haweeleh, T., & Alhowary, A. A. (2026). Maternal Salivary Glutamate Concentrations in Cesarean Delivery: A Prospective Comparison Between Spinal and General Anesthesia. Life, 16(5), 748. https://doi.org/10.3390/life16050748
Vancouver
Bani Hani D, Altal OF, Hulliel AF, Ahmed T, Alrusan A, Al Hazaymeh M, et al. Maternal Salivary Glutamate Concentrations in Cesarean Delivery: A Prospective Comparison Between Spinal and General Anesthesia. Life. 2026;16(5):748. doi:10.3390/life16050748
BibTeX
@article{BaniHani2026,
author = {Bani Hani, Diab and Altal, Omar F and Hulliel, Atef F and Ahmed, Tala and Alrusan, Anas and Al Hazaymeh, Mohammad and Albusta, Fatima and Haweeleh, Taqwa and Alhowary, Ala A},
title = {Maternal Salivary Glutamate Concentrations in Cesarean Delivery: A Prospective Comparison Between Spinal and General Anesthesia},
journal = {Life},
year = {2026},
volume = {16},
number = {5},
pages = {748},
doi = {10.3390/life16050748}
}
EUVIMED