EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Advanced Echocardiographic Characterization of Neonatal Ebstein’s Anomaly Using Myocardial Deformation Imaging: A Single-Center Study

Carmen Corina Șuteu iD, Nicola Şuteu, Liliana Gozar, Oana Cristina Marginean iD, Andreea Cerghit-Paler iD, Maria Oana Săsăran iD, Camelia Râtea iD, Amalia Făgărăşan iD

Life · 14.04.2026 · 16 (4) · 670

DOI: 10.3390/life16040670 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Life, online erschienen am 14.04.2026. Verfasst von Carmen Corina Șuteu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics III, "George Emil Palade" University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 540136 Târgu Mureș, Roma…. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitatea de Medicină, Farmacie, Științe și Tehnologie "George Emil Palade" din Târgu Mureș, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu-Mureș.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Neonatal Ebstein’s anomaly (EA) is a severe condition with significant hemodynamic instability and early myocardial dysfunction, where abnormal right-heart geometry limits conventional echocardiography and highlights the value of myocardial deformation imaging.

Methods

We conducted a single-center retrospective observational study including 16 neonates with EA and 26 healthy neonates. All subjects underwent comprehensive transthoracic echocardiography during the neonatal period. Conventional two-dimensional imaging and speckle-tracking echocardiography (STE) were used to assess biventricular and biatrial myocardial deformation. Deformation parameters were compared between groups, and receiver operating characteristic (ROC) curve analysis evaluated diagnostic performance.

Results

Neonates with EA demonstrated significant structural remodeling and severe biventricular and biatrial dysfunction compared with controls. Speckle-tracking showed markedly reduced right ventricular longitudinal strain (LS) in all segments (all, p < 0.001), particularly in free-wall and four-chamber views. Left ventricular (LV) global LS (GLS) was significantly reduced in neonates with EA compared with controls (−14.53% vs. −22.32%, p < 0.001), indicating early involvement of LV myocardial function in the neonatal period. Atrial reservoir, conduit, and contractile strain were severely impaired in both atria (all, p < 0.001). ROC analysis revealed excellent diagnostic accuracy, especially for LVGLS (AUC 0.919) and right atrial contractile strain (AUC 0.958).

Conclusions

STE enables the early detection of extensive biventricular and biatrial myocardial dysfunction in neonatal EA, including abnormalities not fully captured by conventional echocardiographic parameters, thereby providing significant incremental diagnostic value.

Schlagwörter

Stichwörter der Autor:innen

Ebstein’s anomalyatrial strainmyocardial strainneonatesspeckle-tracking echocardiography

Autor:innen und Institutionen

  • Department of Pediatrics III, "George Emil Palade" University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 540136 Târgu Mureș, Romania.
  • Department of Pediatric Cardiology, Emergency Institute for Cardiovascular Diseases and Transplantation, 540136 Târgu Mureş, Romania.
  • Department of Pediatrics I, "George Emil Palade" University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 540136 Târgu Mureş, Romania.
  • Department of Pediatrics III, Faculty of Medicine English, "George Emil Palade" University of Medicine, Pharmacy, Science, and Technology of Târgu Mureș, 540136 Târgu Mureş, Romania.
  • Moldova & ProNutrition Center, Doctoral School, "Nicolae Testemitanu" State University of Medicine and Pharmacy of the Republic of Moldova, MD-2004 Chişinău, Moldova.

ORCID-Profile: Carmen Corina Șuteu, Oana Cristina Marginean, Andreea Cerghit-Paler, Maria Oana Săsăran, Camelia Râtea, Amalia Făgărăşan

Förderung

  • Universitatea de Medicină, Farmacie, Științe și Tehnologie "George Emil Palade" din Târgu Mureș
  • George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Târgu-Mureș

Zitieren

APA

Șuteu, C. C., Şuteu, N., Gozar, L., Marginean, O. C., Cerghit-Paler, A., Săsăran, M. O., Râtea, C., & Făgărăşan, A. (2026). Advanced Echocardiographic Characterization of Neonatal Ebstein’s Anomaly Using Myocardial Deformation Imaging: A Single-Center Study. Life, 16(4), 670. https://doi.org/10.3390/life16040670

Vancouver

Șuteu CC, Şuteu N, Gozar L, Marginean OC, Cerghit-Paler A, Săsăran MO, et al. Advanced Echocardiographic Characterization of Neonatal Ebstein’s Anomaly Using Myocardial Deformation Imaging: A Single-Center Study. Life. 2026;16(4):670. doi:10.3390/life16040670

BibTeX
@article{uteu2026,
  author = {Șuteu, Carmen Corina and Şuteu, Nicola and Gozar, Liliana and Marginean, Oana Cristina and Cerghit-Paler, Andreea and Săsăran, Maria Oana and Râtea, Camelia and Făgărăşan, Amalia},
  title = {Advanced Echocardiographic Characterization of Neonatal Ebstein’s Anomaly Using Myocardial Deformation Imaging: A Single-Center Study},
  journal = {Life},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {670},
  doi = {10.3390/life16040670}
}
Kostenlos starten →