EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Evaluation of Relative Left Ventricular Wall Thickness on Echocardiography for the Diagnosis of ATTR Cardiac Amyloidosis

Shunsuke Kiuchi iD, Shinji Hisatake, Hidenobu Hashimoto iD, Yoshiki Murakami, Takanori Ikeda

Life · 26.03.2026 · 16 (4) · 549

DOI: 10.3390/life16040549 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Life, online erschienen am 26.03.2026. Verfasst von Shunsuke Kiuchi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Medicine, Department of Internal Medicine, Toho University Faculty of Medicine, Tokyo 143-8541, Japan. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The number of patients with transthyretin amyloid cardiomyopathy (ATTR-CM) has been increasing recently, and the early diagnosis and treatment of it are important. 99mTc pyrophosphate scintigraphy (99mTc-PYP) plays a key role in the early diagnosis of ATTR-CM. In patients who underwent 99mTc-PYP, the early diagnosis of ATTR-CM by echocardiography was evaluated, focusing on left ventricular myocardial form and left ventricular wall thickness.

Methods

The present study was conducted on 144 patients who underwent 99mTc-PYP between February 2020 and March 2024. A comparison was made between the 99mTc-PYP positive (P) and negative (N) groups, and significant factors were subjected to multivariate analysis.

Results

17 of 144 patients were positive (14.9%), and 15 patients were diagnosed with ATTR-CM by myocardial or skin (fat) biopsy. Other positive patients were also clinically considered to have ATTR-CM based on findings such as poor cardiac function and cerebral hemorrhage. 99mTc-PYP positive had a significantly larger CTR (60.3% in the P group vs. 53.9% in the N group, p = 0.007) and a larger left atrial diameter (42.8 mm in the P group vs. 40.0 mm in the N group, p = 0.047). On the other hand, the mean LV wall thickness was significantly thicker (15.7 mm in the P group vs. 12.8 mm in the N group, p < 0.001); however the LV end-diastolic diameter was smaller (41.9 mm in the P group vs. 48.4 mm in the P group, p < 0.001). The LV mass was similar in both groups, thus the relative left ventricular wall thickness (RWT), which indicates relative wall thickening, was significantly higher in the P group (0.85 in the P group vs. 0.52 mm in the N group, p < 0.001). The receiver operating characteristic curve of RWT for assessing 99mTc-PYP positivity had a cut-off value of 0.717 (area under the curve 0.862, 95%CI 0.763–0.961).

Conclusions

The evaluation of wall thickness and RWT on echocardiography is important for diagnosing ATTR-CM.

Schlagwörter

Stichwörter der Autor:innen

99mTc-labeled pyrophosphate scintigraphyechocardiographyrelative left ventricular wall thicknesstransthyretin cardiac amyloidosis

Autor:innen und Institutionen

  • Division of Cardiovascular Medicine, Department of Internal Medicine, Toho University Faculty of Medicine, Tokyo 143-8541, Japan.

ORCID-Profile: Shunsuke Kiuchi, Hidenobu Hashimoto

Zitieren

APA

Kiuchi, S., Hisatake, S., Hashimoto, H., Murakami, Y., & Ikeda, T. (2026). The Evaluation of Relative Left Ventricular Wall Thickness on Echocardiography for the Diagnosis of ATTR Cardiac Amyloidosis. Life, 16(4), 549. https://doi.org/10.3390/life16040549

Vancouver

Kiuchi S, Hisatake S, Hashimoto H, Murakami Y, Ikeda T. The Evaluation of Relative Left Ventricular Wall Thickness on Echocardiography for the Diagnosis of ATTR Cardiac Amyloidosis. Life. 2026;16(4):549. doi:10.3390/life16040549

BibTeX
@article{Kiuchi2026,
  author = {Kiuchi, Shunsuke and Hisatake, Shinji and Hashimoto, Hidenobu and Murakami, Yoshiki and Ikeda, Takanori},
  title = {The Evaluation of Relative Left Ventricular Wall Thickness on Echocardiography for the Diagnosis of ATTR Cardiac Amyloidosis},
  journal = {Life},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {549},
  doi = {10.3390/life16040549}
}
Kostenlos starten →