Antenatal and Postnatal Ultrasound Factors Associated with Surgical Intervention in Antenatally Diagnosed Hydronephrosis
Kidney and Dialysis · 13.11.2026 · 6 (4) · 72
DOI: 10.3390/kidneydial6040072 ↗Kurz gefasst
Fachartikel in der Zeitschrift Kidney and Dialysis, online erschienen am 13.11.2026. Verfasst von Kritika Sanganeria und 7 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Predicting the need for surgical intervention in infants with antenatally diagnosed hydronephrosis (ANH) remains challenging. This study aimed to identify antenatal and postnatal factors associated with surgical intervention in infants with ANH.
Method
This prospective observational study included infants aged less than 6 months with antenatally diagnosed hydronephrosis. Antenatal Society for Fetal Urology (SFU) and anterior–posterior pelvic diameter (APD) grades were obtained from maternal antenatal ultrasound reports, and the infants were followed for 6 months after birth. Demographic characteristics and antenatal and postnatal radiological findings were compared between infants who underwent surgical intervention and those managed conservatively. SFU and APD grades were also compared according to postnatal outcomes. In addition, the association of postnatal APD with surgical intervention was evaluated, and an exploratory cutoff value was determined.
Result
Among 53 infants with antenatally diagnosed hydronephrosis, 18 had bilateral hydronephrosis, yielding a total of 71 renal units for renal-unit level analyses, 16 (22.5%) required surgery. Infants undergoing surgery had reduced renal parenchymal thickness, higher SFU grades (III/IV), greater postnatal APD (29.5 vs. 7.8 mm; p ≤ 0.001), and less preserved corticomedullary differentiation (31.2% vs. 92.7%; p < 0.001). Higher APD grade (OR 6.3, 95% CI 1.9–26.5; p = 0.001), SFU grade (OR 6.64, 95% CI 2.1–21.0; p = 0.001), and postnatal APD (OR 1.16, 95% CI 1.06–1.29; p = 0.004) were independently associated with surgical intervention. A postnatal APD cutoff of 13 mm showed good diagnostic accuracy (AUC = 0.87 (95% CI 0.77–0.96), p = 0.001).
Conclusion
Antenatal SFU grade and APD grade and postnatal APD were strongly associated with subsequent surgical intervention and represented key factors influencing surgical decision-making during follow-up.
Zitieren
APA
Sanganeria, K., Padubidri, S. P., Prarthana, S., Nagaraju, S. P., Bhojaraja, M. V., Rangaswamy, D., Swaminathan, S. M., & Shiva, P. S. (2026). Antenatal and Postnatal Ultrasound Factors Associated with Surgical Intervention in Antenatally Diagnosed Hydronephrosis. Kidney and Dialysis, 6(4), 72. https://doi.org/10.3390/kidneydial6040072
Vancouver
Sanganeria K, Padubidri SP, Prarthana S, Nagaraju SP, Bhojaraja MV, Rangaswamy D, et al. Antenatal and Postnatal Ultrasound Factors Associated with Surgical Intervention in Antenatally Diagnosed Hydronephrosis. Kidney and Dialysis. 2026;6(4):72. doi:10.3390/kidneydial6040072
BibTeX
@article{Sanganeria2026,
author = {Sanganeria, Kritika and Padubidri, Santosh Prabhu and Prarthana, Sharvani and Nagaraju, Shankar Prasad and Bhojaraja, Mohan V. and Rangaswamy, Dharshan and Swaminathan, Shilna Muttickal and Shiva, Prasad Seetharam},
title = {Antenatal and Postnatal Ultrasound Factors Associated with Surgical Intervention in Antenatally Diagnosed Hydronephrosis},
journal = {Kidney and Dialysis},
year = {2026},
volume = {6},
number = {4},
pages = {72},
doi = {10.3390/kidneydial6040072}
}
EUVIMED