Intraoperative Flow Measurement as a Quality Control during Carotid Endarterectomy in a Teaching Hospital Setting

Anna E. Cyrek, Johannes Bernheim, Benjamin Juntermanns, Wieslaw Burzec, Peri Husen, Sonia Radunz, Arkadius Pacha, Christian Weimar, Jürgen Treckmann, Johannes N. Hoffmann

Journal of Vascular Diseases · 2022

DOI: 10.3390/jvd1010008 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vascular Diseases, 2022. Verfasst von Anna E. Cyrek und 9 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To evaluate the technical results of an arterial repair, a variety of intraoperative imaging and assessment techniques can be used during carotid endarterectomy (CEA). The aim of the study was to evaluate the usefulness of intraoperative ultrasound flow measurement as a quality control after primary CEA in a teaching hospital setting.

Methods

Over 36 months, 107 consecutive CEAs were performed at our institution. Retrospectively acquired demographics, intraoperative flow measurements, duplex results, revisions, and surgical outcomes were reviewed. Postoperative 30-day transient ischemic attack (TIA), stroke, and death rates were analyzed. Results were compared with ultrasound flow measurement and duplex ultrasonography.

Results

From March 2012 to March 2015, 107 primary consecutive CEAs were performed in 107 patients (71% male, 29% female), whose age ranged from 51 to 81 years with a mean age of 68 ± 4 years. Associated risk factors included diabetes for 89 (83%), smoking for 92 (86%), hypertension for 94 (87.8%), chronic renal insufficiency for 71 (66%), and coronary artery disease for 57 (53%) of the patients. Early postoperative duplex scans in all 107 patients showed no significant changes from intraoperative findings. The ipsilateral stroke and death rate in this study was 0 (0/107) and the 30-day death and stroke rate was also 0 (0/107), with no significant difference between trainees and senior surgeons. Three patients (2.8%) had flow < 100 mL/Min and two of them were revised after completion of contrast angiography.

Conclusions

The findings of this study indicate that the intraoperative flow measurement is an alternative method for detecting technical errors and a tool for quality-control imaging. Especially for trainees, it makes sense to ensure effectiveness of the procedure upon its completion and to assess the technical adequacy of CEA.

Zitieren

APA

Cyrek, A. E., Bernheim, J., Juntermanns, B., Burzec, W., Husen, P., Radunz, S., Pacha, A., Weimar, C., Treckmann, J., & Hoffmann, J. N. (2022). Intraoperative Flow Measurement as a Quality Control during Carotid Endarterectomy in a Teaching Hospital Setting. Journal of Vascular Diseases. https://doi.org/10.3390/jvd1010008

Vancouver

Cyrek AE, Bernheim J, Juntermanns B, Burzec W, Husen P, Radunz S, et al. Intraoperative Flow Measurement as a Quality Control during Carotid Endarterectomy in a Teaching Hospital Setting. Journal of Vascular Diseases. 2022. doi:10.3390/jvd1010008

BibTeX
@article{Cyrek2022,
  author = {Cyrek, Anna E. and Bernheim, Johannes and Juntermanns, Benjamin and Burzec, Wieslaw and Husen, Peri and Radunz, Sonia and Pacha, Arkadius and Weimar, Christian and Treckmann, Jürgen and Hoffmann, Johannes N.},
  title = {Intraoperative Flow Measurement as a Quality Control during Carotid Endarterectomy in a Teaching Hospital Setting},
  journal = {Journal of Vascular Diseases},
  year = {2022},
  doi = {10.3390/jvd1010008}
}
Kostenlos starten →