Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report
Journal of Personalized Medicine · 02.11.2026 · 16 (11) · 570
DOI: 10.3390/jpm16110570 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Personalized Medicine, online erschienen am 02.11.2026. Verfasst von Dragan Klarić und 2 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Reanimation
Abstract (Originalsprache)
Background
Dialyzer-associated hypersensitivity reactions are rare but potentially life-threatening complications of hemodialysis (HD). Their pathophysiology is heterogeneous.
Methods
We report a 49-year-old patient with end-stage chronic kidney disease (CKD G5), severe secondary hyperparathyroidism, poorly controlled arterial hypertension, a long history of heavy smoking, severe coronary and valvular disease, reduced left ventricular ejection fraction, renal anemia, and chronic volume overload.
Results
Shortly after initiation of HD with a polysulfone dialyzer (Diacap Pro), she repeatedly developed severe dyspnea, hypoxemia, and marked hypertensive responses. Similar reactions occurred after switching to a cellulose triacetate dialyzer (Sureflux), necessitating temporary conversion to peritoneal dialysis (PD). Progressive PD ultrafiltration failure and loss of residual kidney function eventually required a return to HD. Severe reactions recurred within 15–30 min of treatment despite premedication. During the most severe episode, the patient developed profound hypoxemia (SpO2 55%), severe hypertension (up to 240/130 mmHg), ventricular tachycardia, and cardiac arrest requiring successful cardiopulmonary resuscitation. Immunological evaluation demonstrated normal total IgE (17 U/mL), decreased C3 (0.76 g/L), markedly reduced total hemolytic complement activity (CH50, 18%), and elevated IL-6 (87.5 pg/mL). Chronic HD was successfully reinitiated using an FX CorAL dialyzer with a Helixone® hydro membrane. Since its introduction, no further hypersensitivity reactions have occurred, and corticosteroid, antihistamine, and bronchodilator premedication has been discontinued. This case demonstrates severe recurrent dialyzer-associated hypersensitivity with findings suggestive of complement involvement, complicated by cardiac arrest in a patient with markedly impaired cardiovascular reserve.
Conclusions
Successful long-term treatment with a hydrophilic Helixone® dialyzer highlights the importance of individualized dialyzer selection in patients with severe hypersensitivity reactions.
Zitieren
APA
Klarić, D., Katalinić, L., & Klarić, M. (2026). Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report. Journal of Personalized Medicine, 16(11), 570. https://doi.org/10.3390/jpm16110570
Vancouver
Klarić D, Katalinić L, Klarić M. Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report. Journal of Personalized Medicine. 2026;16(11):570. doi:10.3390/jpm16110570
BibTeX
@article{Klari2026,
author = {Klarić, Dragan and Katalinić, Lea and Klarić, Marta},
title = {Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report},
journal = {Journal of Personalized Medicine},
year = {2026},
volume = {16},
number = {11},
pages = {570},
doi = {10.3390/jpm16110570}
}
EUVIMED