Tracking False Lumen Remodeling with AI: A Variational Autoencoder Approach After Frozen Elephant Trunk Surgery
Journal of Personalized Medicine · 11.10.2025 · 15 (10) · 486
DOI: 10.3390/jpm15100486 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Personalized Medicine, online erschienen am 11.10.2025. Verfasst von Anja Osswald und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Centre, University Duisburg-Essen, 45122 Essen, Germany. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Research Foundation, Faculty of Medicine, University of Duisburg-Essen, Add-on Fellowship of the Joachim Herz Foundation.
Abstract (Originalsprache)
Objective
False lumen (FL) thrombosis plays a key role in aortic remodeling after Frozen Elephant Trunk (FET) surgery, yet current imaging assessments are limited to categorical classifications. This study aimed to evaluate an unsupervised artificial intelligence (AI) algorithm based on a variational autoencoder (VAE) for automated, continuous quantification of FL thrombosis using serial computed tomography angiography (CTA).
Methods
In this retrospective study, a VAE model was applied to axial CTA slices from 30 patients with aortic dissection who underwent FET surgery. The model encoded each image into a structured latent space, from which a continuous “thrombus score” was developed and derived to quantify the extent of FL thrombosis. Thrombus scores were compared between postoperative and follow-up scans to assess individual remodeling trajectories.
Results
The VAE successfully encoded anatomical features of the false lumen into a structured latent space, enabling unsupervised classification of thrombus states. A continuous thrombus score was derived from this space, allowing slice-by-slice quantification of thrombus burden across the aorta. The algorithm demonstrated robust reconstruction accuracy and consistent separation of fully patent, partially thrombosed, and completely thrombosed lumen states without the need for manual annotation. Across the cohort, 50% of patients demonstrated an increase in thrombus score over time, 40% a decrease, and 10% remained unchanged. Despite these individual differences, no statistically significant change in overall thrombus burden was observed at the group level (p = 0.82), emphasizing the importance of individualized longitudinal assessment.
Conclusions
The VAE-based method enables reproducible, annotation-free quantification of FL thrombosis and captures patient-specific remodeling patterns. This approach may enhance post-FET surveillance and supports the integration of AI-driven tools into personalized aortic imaging workflows.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Centre, University Duisburg-Essen, 45122 Essen, Germany.
- Department of Vascular Surgery, Houston Methodist DeBakey Heart & Vascular Center, Houston, TX 77030, USA.
- Translational Imaging Centre, Houston Methodist Research Institute, Houston, TX 77030, USA.
ORCID-Profile: Anja Osswald, Sharaf-Eldin Shehada, Matthias Thielmann, Payam Akhyari
Förderung
- German Research Foundation
- Faculty of Medicine, University of Duisburg-Essen
- Add-on Fellowship of the Joachim Herz Foundation
Zitieren
APA
Osswald, A., Shehada, S. E., Thielmann, M., Lumsden, A. B., Akhyari, P., & Karmonik, C. (2025). Tracking False Lumen Remodeling with AI: A Variational Autoencoder Approach After Frozen Elephant Trunk Surgery. Journal of Personalized Medicine, 15(10), 486. https://doi.org/10.3390/jpm15100486
Vancouver
Osswald A, Shehada SE, Thielmann M, Lumsden AB, Akhyari P, Karmonik C. Tracking False Lumen Remodeling with AI: A Variational Autoencoder Approach After Frozen Elephant Trunk Surgery. Journal of Personalized Medicine. 2025;15(10):486. doi:10.3390/jpm15100486
BibTeX
@article{Osswald2025,
author = {Osswald, Anja and Shehada, Sharaf-Eldin and Thielmann, Matthias and Lumsden, Alan B and Akhyari, Payam and Karmonik, Christof},
title = {Tracking False Lumen Remodeling with AI: A Variational Autoencoder Approach After Frozen Elephant Trunk Surgery},
journal = {Journal of Personalized Medicine},
year = {2025},
volume = {15},
number = {10},
pages = {486},
doi = {10.3390/jpm15100486}
}