Computational Fluid Dynamics Approach for Direct Nose-to-Brain Drug Delivery: A Systematic Review and Meta-Analysis
Journal of Personalized Medicine · 24.09.2025 · 15 (10) · 447
DOI: 10.3390/jpm15100447 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Personalized Medicine, online erschienen am 24.09.2025. Verfasst von Priya Vishnumurthy und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nemera La Verpillière, 69007 Lyon, France. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nemera (France), Nemera La Verpillère.
Abstract (Originalsprache)
Background/Objectives: Optimizing drug deposition to the olfactory region is key in Nose-to-brain drug delivery strategies. However, findings from computational fluid dynamics (CFD) studies remain inconsistent concerning the parameters influencing olfactory deposition, limiting clinical translation and device optimization. This systematic review aims to identify robust CFD parameters for optimizing drug delivery to the olfactory region.
Methods
A systematic review and meta-analysis were conducted following PRISMA guidelines, selecting studies reporting CFD simulations of nasal drug delivery with evaluation of olfactory deposition efficiency. The primary outcome was the correlation between each CFD parameter and olfactory deposition rate. Parameters included particle size, impaction parameter, flow rate, spray cone angle, insertion angle, injection velocity, head position, release position, and breathing pattern. Data were extracted and standardized, and statistical methods were used to assess correlations, heterogeneity, and potential biases in study results.
Results
Smaller particle size (pooled r = −0.42) and lower impaction parameter (r = −0.39) were significantly associated with higher olfactory deposition. No consistent correlation was observed with breathing flow rate. Heterogeneity across studies was high (I2 > 90%). Funnel plots asymmetry suggested potential publication bias in particle-related outcomes.
Conclusions
Particle characteristics, especially size and inertia, are the most critical determinants of olfactory deposition in CFD simulations. These findings support design optimization of nasal delivery devices targeting the olfactory region and underscore the need for standardized reporting and validation across CFD studies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Nemera La Verpillière, 69007 Lyon, France.
- Aix Marseille University, CNRS, IUSTI, 13013 Marseille, France.
- Aix Marseille University, APHM, CNRS, IUSTI, La Conception University Hospital, Oto-Rhino-Laryngology and Head and Neck Surgery Department, 13005 Marseille, France.
Förderung
- Nemera (France)
- Nemera La Verpillère
Zitieren
APA
Vishnumurthy, P., Radulesco, T., Bouchet, G., Regard, A., & Michel, J. (2025). Computational Fluid Dynamics Approach for Direct Nose-to-Brain Drug Delivery: A Systematic Review and Meta-Analysis. Journal of Personalized Medicine, 15(10), 447. https://doi.org/10.3390/jpm15100447
Vancouver
Vishnumurthy P, Radulesco T, Bouchet G, Regard A, Michel J. Computational Fluid Dynamics Approach for Direct Nose-to-Brain Drug Delivery: A Systematic Review and Meta-Analysis. Journal of Personalized Medicine. 2025;15(10):447. doi:10.3390/jpm15100447
BibTeX
@article{Vishnumurthy2025,
author = {Vishnumurthy, Priya and Radulesco, Thomas and Bouchet, Gilles and Regard, Alain and Michel, Justin},
title = {Computational Fluid Dynamics Approach for Direct Nose-to-Brain Drug Delivery: A Systematic Review and Meta-Analysis},
journal = {Journal of Personalized Medicine},
year = {2025},
volume = {15},
number = {10},
pages = {447},
doi = {10.3390/jpm15100447}
}
EUVIMED