EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cataract Surgery in Pseudoexfoliation Syndrome Using the Eight-Chop Technique

Tsuyoshi Sato iD

Journal of Personalized Medicine · 25.08.2025 · 15 (9) · 396

DOI: 10.3390/jpm15090396 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Personalized Medicine, online erschienen am 25.08.2025. Verfasst von Tsuyoshi Sato. Beteiligte Einrichtung: Department of Ophthalmology, Sato Eye Clinic, Nemoto 3-3, Matsudo-shi 271-0077, Chiba-ken, Japan. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to evaluate the safety and efficacy of the eight-chop technique in cataract surgery in patients with pseudoexfoliation (PEX) syndrome and assess the intraoperative parameters, changes in corneal endothelial cells, intraocular pressure (IOP), and intraoperative complications.

Methods

This technique was applied in patients with and without PEX syndrome. Preoperative and postoperative assessments were conducted on best-corrected visual acuity, IOP, corneal endothelial cell density (CECD), coefficient of variation, percentage of hexagonal cells, and central corneal thickness. Intraoperative recordings included operative time, phaco time, aspiration time, cumulative dissipated energy (CDE), and fluid of volume used.

Results

We analyzed 150 eyes from 150 patients (mean age, 75.5 ± 5.7 years; 59 men, 91 women). In the PEX group, operative time, phaco time, aspiration time, CDE, and volume of fluid used were 6.7 min, 17.4 s, 85.2 s, 6.91 µJ, and 33.4 mL, respectively, demonstrating favorable surgical metrics. On the other hand, in the control group, operative time, phaco time, aspiration time, CDE, and volume of fluid used were 4.5 min, 14.3 s, 64.0 s, 5.83 µJ, and 25.5 mL, respectively. In addition, CECD losses were 3.7% at week 7 and 2.7% at week 19 in the PEX group and 2.7% and 1.6%, respectively, in the control group. Significant decreases were observed at 7 and 19 weeks postoperatively in the PEX and control groups. No eye in the PEX group required a capsular tension ring due to zonular dialysis.

Conclusions

The eight-chop technique in cataract surgery demonstrates excellent intraoperative parameters in patients with PEX, is effective against zonular weakness, and does not require the use of a capsular tension ring. This technique will aid in establishing personalized treatment strategies and improve cataract management and treatment.

Schlagwörter

Stichwörter der Autor:innen

cataract surgerycorneal endothelial celleight-chop techniquepersonalized treatmentphacoemulsificationpseudoexfoliation syndrome

Autor:innen und Institutionen

  • Department of Ophthalmology, Sato Eye Clinic, Nemoto 3-3, Matsudo-shi 271-0077, Chiba-ken, Japan.

ORCID-Profile: Tsuyoshi Sato

Zitieren

APA

Sato, T. (2025). Cataract Surgery in Pseudoexfoliation Syndrome Using the Eight-Chop Technique. Journal of Personalized Medicine, 15(9), 396. https://doi.org/10.3390/jpm15090396

Vancouver

Sato T. Cataract Surgery in Pseudoexfoliation Syndrome Using the Eight-Chop Technique. Journal of Personalized Medicine. 2025;15(9):396. doi:10.3390/jpm15090396

BibTeX
@article{Sato2025,
  author = {Sato, Tsuyoshi},
  title = {Cataract Surgery in Pseudoexfoliation Syndrome Using the Eight-Chop Technique},
  journal = {Journal of Personalized Medicine},
  year = {2025},
  volume = {15},
  number = {9},
  pages = {396},
  doi = {10.3390/jpm15090396}
}
Kostenlos starten →