EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Subcutaneous versus Transvenous Implantable Cardioverter Defibrillator in Patients with End-Stage Renal Disease Requiring Dialysis: Extended Long-Term Retrospective Multicenter Follow-Up

Fabian Schiedat iD, Benjamin Meuterodt iD, Joachim Winter iD, Magnus Prull, Assem Aweimer, Michael Gotzmann, Stephen O'Connor, Christian Perings, Thomas Lawo, Ibrahim El-Battrawy, Christoph Hanefeld, Johannes Korth iD und 2 weitere

Journal of Personalized Medicine · 17.08.2024 · 14 (8) · 870

DOI: 10.3390/jpm14080870 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Personalized Medicine, online erschienen am 17.08.2024. Verfasst von Fabian Schiedat und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology and Angiology, Marienhospital Gelsenkirchen, Academic Hospital of the Ruhr University Bochum, 45886 Gelsenkirchen, Germany. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Implantable cardioverter defibrillators (ICD) prevent sudden cardiac death (SCD). Patients with end-stage renal disease (ESRD) requiring dialysis are at a very high risk of infection from cardiac implantable electronic device (CIED) implantation as well as mortality. In the present study, we compared the long-term complications and outcomes between subcutaneous ICD (S-ICD) and transvenous ICD (TV-ICD) recipients.

Methods

In this retrospective analysis, we analyzed a total of 43 patients with ESRD requiring dialysis who received either a prophylactic S-ICD (26 patients) or a single right ventricular lead TV-ICD (17 patients) at seven experienced centers in Germany. Follow-up was performed bi-annually, at the end of which the data concerning comorbidities and, if applicable, reason for death were checked and confirmed with patients’ general practitioner, nephrologist and cardiologist.

Results

The median follow up duration was 95.6 months (range 42.8–126.3 months). Baseline characteristics were without noteworthy significant differences between groups. During follow-up (FU), there were significantly more device-associated infections (HR 8.72, 95% confidence interval (CI), 1.18 to 12.85, p < 0.05) and device-associated hospitalizations (HR 10.20, 95% CI 1.22 to 84.61, p < 0.001), as well as a higher cardiovascular mortality (HR 9.17, 95% CI 1.12 to 8.33, p < 0.05), in the TV-ICD group. The number of patients requiring hospitalization for any reason was significantly higher in the TV-ICD group (HR 2.59, 95% CI 1.12 to 6.41, p < 0.05). There was no significant difference in overall mortality (HR 1.92, 95% CI 0.96 to 6.15, p = 0.274).

Conclusions

Our data suggest that, in this extended follow-up in seriously compromised renal patients on dialysis, the S-ICD patients have statistically fewer device infections and hospitalizations as well as lower cardiac mortality compared with the TV-ICD cohort.

Schlagwörter

Stichwörter der Autor:innen

CIED infectionS-ICDTV-ICDend-stage renal diseasehemodialysisimplantable cardiac defibrillatorsudden cardiac death

Autor:innen und Institutionen

  • Department of Cardiology and Angiology, Marienhospital Gelsenkirchen, Academic Hospital of the Ruhr University Bochum, 45886 Gelsenkirchen, Germany.
  • Department of Cardiology and Angiology, University Hospital Bergmannsheil Bochum of the Ruhr-University Bochum, 44789 Bochum, Germany.
  • Department of Cardiology, Electrophysiology, Pneumology and Intensive Care Medicine, St. Marien-Hospital Luenen, Academic Hospital of the University Muenster, 44534 Lünen, Germany.
  • Department of Cardiovascular Surgery, Heinrich-Heine University Hospital, 40225 Duesseldorf, Germany.
  • Department of Cardiology, Augusta Hospital Bochum, Academic Hospital of the University Duisburg Essen, 44791 Bochum, Germany.
  • Department of Cardiology, Katholische Kliniken Bochum of the Ruhr University Bochum, 44791 Bochnum, Germany.

ORCID-Profile: Fabian Schiedat, Benjamin Meuterodt, Joachim Winter, Johannes Korth, Andreas Mügge

Zitieren

APA

Schiedat, F., Meuterodt, B., Winter, J., Prull, M., Aweimer, A., Gotzmann, M., O'Connor, S., Perings, C., Lawo, T., El-Battrawy, I., Hanefeld, C., Korth, J., Mügge, A., & Kloppe, A. (2024). Subcutaneous versus Transvenous Implantable Cardioverter Defibrillator in Patients with End-Stage Renal Disease Requiring Dialysis: Extended Long-Term Retrospective Multicenter Follow-Up. Journal of Personalized Medicine, 14(8), 870. https://doi.org/10.3390/jpm14080870

Vancouver

Schiedat F, Meuterodt B, Winter J, Prull M, Aweimer A, Gotzmann M, et al. Subcutaneous versus Transvenous Implantable Cardioverter Defibrillator in Patients with End-Stage Renal Disease Requiring Dialysis: Extended Long-Term Retrospective Multicenter Follow-Up. Journal of Personalized Medicine. 2024;14(8):870. doi:10.3390/jpm14080870

BibTeX
@article{Schiedat2024,
  author = {Schiedat, Fabian and Meuterodt, Benjamin and Winter, Joachim and Prull, Magnus and Aweimer, Assem and Gotzmann, Michael and O'Connor, Stephen and Perings, Christian and Lawo, Thomas and El-Battrawy, Ibrahim and Hanefeld, Christoph and Korth, Johannes and Mügge, Andreas and Kloppe, Axel},
  title = {Subcutaneous versus Transvenous Implantable Cardioverter Defibrillator in Patients with End-Stage Renal Disease Requiring Dialysis: Extended Long-Term Retrospective Multicenter Follow-Up},
  journal = {Journal of Personalized Medicine},
  year = {2024},
  volume = {14},
  number = {8},
  pages = {870},
  doi = {10.3390/jpm14080870}
}
Kostenlos starten →