EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fluid Responsiveness Is Associated with Successful Weaning after Liver Transplant Surgery

Fluid-Responsiveness ist mit erfolgreichem Weaning nach Lebertransplantationsoperation verbunden

Ricardo Castro iD, Pablo Born, Felipe Muñoz, Camila Guzmán, Eduardo Kattan, Glenn Hernandez, Jan Bakker

Journal of Personalized Medicine · 18.04.2024 · 14 (4) · 429

DOI: 10.3390/jpm14040429 ↗

Auf einen Blick

Bei 15 beatmeten Patient:innen nach Lebertransplantation war Fluid-Responsiveness vor dem Spontanatmungsversuch mit erfolgreicher Extubation verbunden. Bei fluid-unresponsiven Patient:innen traten häufiger Weaning-Schwierigkeiten auf.

Fragestellung

Ist eine individuelle Beurteilung der Fluid-Responsiveness vor einem Spontanatmungsversuch mit weniger Extubationsversagen bei intensivpflichtigen Patient:innen nach Lebertransplantation verbunden?

Methode

15 LT-Patient:innen wurden 2023 eingeschlossen. Fluid-Responsiveness wurde per Passive-Leg-Raising bei ICU-Aufnahme und vor SBT geprüft; kardialer Index vor und nach SBT erfasst.

Ergebnisse

7 Patient:innen waren bei T1 fluid-responsive, 12 bei T2. Bei fluid-responsiven Patient:innen stieg der CI während des SBT von 3.1 {2.8, 3.7} auf 3.7 {3.4, 4.1} mL/min/m2 (p = 0.045). Alle fluid-responsiven Patient:innen bei T2 wurden extubiert.

Einschränkungen

Kleine Fallzahl von 15 Patient:innen; keine signifikanten Unterschiede in hämodynamischen, respiratorischen und Perfusionsparametern.

Schlussfolgerung der Autor:innen

Fluid-responsive Patient:innen nach Lebertransplantation können laut Autor:innen früher mit dem Weaning beginnen und trotz hoher postoperativer Flüssigkeitsbilanz erfolgreich extubiert werden.

Kernaussagen

  • 15 LT-Patient:innen mit postoperativer Flüssigkeitsbilanz von +4476 {3697, 5722} mL
  • Fluid-Response bei T2: alle extubiert nach SBT
  • Bei fluid-unresponsiven Patient:innen traten häufiger Weaning-Schwierigkeiten auf

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Personalized Medicine, online erschienen am 18.04.2024. Verfasst von Ricardo Castro und 6 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago Centro, Santiago 8330074, RM, Chile. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fondo Nacional de Desarrollo Científico y Tecnológico, FONDECYT.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A positive fluid balance may evolve to fluid overload and associate with organ dysfunctions, weaning difficulties, and increased mortality in ICU patients. We explored whether individualized fluid management, assessing fluid responsiveness via a passive leg-raising maneuver (PLR) before a spontaneous breathing trial (SBT), is associated with less extubation failure in ventilated patients with a high fluid balance admitted to the ICU after liver transplantation (LT). We recruited 15 LT patients in 2023. Their postoperative fluid balance was +4476 {3697, 5722} mL. PLR maneuvers were conducted upon ICU admission (T1) and pre SBT (T2). Cardiac index (CI) changes were recorded before and after each SBT (T3). Seven patients were fluid-responsive at T1, and twelve were responsive at T2. No significant differences occurred in hemodynamic, respiratory, and perfusion parameters between the fluid-responsive and fluid-unresponsive patients at any time. Fluid-responsive patients at T1 and T2 increased their CI during SBT from 3.1 {2.8, 3.7} to 3.7 {3.4, 4.1} mL/min/m2 (p = 0.045). All fluid-responsive patients at T2 were extubated after the SBTs and consolidated extubation. Two out of three of the fluid-unresponsive patients experienced weaning difficulties. We concluded that fluid-responsive patients post LT may start weaning earlier and achieve successful extubation despite a high postoperative fluid balance. This highlights the profound impact of personalized assessments of cardiovascular state on critical surgical patients.

Schlagwörter

Stichwörter der Autor:innen

fluid overloadfluid responsivenesspassive leg raisingspontaneous breathing trial

Autor:innen und Institutionen

  • Departamento de Medicina Intensiva, Facultad de Medicina, Pontificia Universidad Católica de Chile, Santiago Centro, Santiago 8330074, RM, Chile.
  • Hospital Clinico UC-CHRISTUS, Pontificia Universidad Católica de Chile, Santiago Centro, Santiago 8330024, RM, Chile.
  • Department of Intensive Care, Erasmus MC University Medical Center, P.O. Box 2040, 3000 Rotterdam, The Netherlands.
  • Department of Pulmonology and Critical Care, Columbia University Medical Center, New York, NY 10019, USA.
  • NYU School of Medicine, Langone, New York, NY 10016, USA.

ORCID-Profile: Ricardo Castro

Förderung

  • Fondo Nacional de Desarrollo Científico y Tecnológico
  • FONDECYT

Zitieren

APA

Castro, R., Born, P., Muñoz, F., Guzmán, C., Kattan, E., Hernandez, G., & Bakker, J. (2024). Fluid Responsiveness Is Associated with Successful Weaning after Liver Transplant Surgery. Journal of Personalized Medicine, 14(4), 429. https://doi.org/10.3390/jpm14040429

Vancouver

Castro R, Born P, Muñoz F, Guzmán C, Kattan E, Hernandez G, et al. Fluid Responsiveness Is Associated with Successful Weaning after Liver Transplant Surgery. Journal of Personalized Medicine. 2024;14(4):429. doi:10.3390/jpm14040429

BibTeX
@article{Castro2024,
  author = {Castro, Ricardo and Born, Pablo and Muñoz, Felipe and Guzmán, Camila and Kattan, Eduardo and Hernandez, Glenn and Bakker, Jan},
  title = {Fluid Responsiveness Is Associated with Successful Weaning after Liver Transplant Surgery},
  journal = {Journal of Personalized Medicine},
  year = {2024},
  volume = {14},
  number = {4},
  pages = {429},
  doi = {10.3390/jpm14040429}
}
Kostenlos starten →