Fachartikel in der Zeitschrift Journal of Personalized Medicine, online erschienen am 29.04.2023. Verfasst von Julien Berhouet und 5 weiteren Autor:innen. Beteiligte Einrichtung: CHRU Trousseau Service d'Orthopédie Traumatologie, Faculté de Médecine de Tours, Université de Tours, 1C Avenue de la République, 37170 Tours, France. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
The purpose of this study was to analyze the real range of motion (RoM) measured in patients operated on for reverse shoulder arthroplasty (RSA) and compare it to the virtual RoM provided by the preoperative planning software. Hypothesis: There was a difference between virtual and real RoM, which can be explained by different factors, specifically the scapula-thoracic (ST) joint.
Methods
Twenty patients with RSA were assessed at a minimum follow-up of 18 months. Passive RoM in forward elevation abduction, without and with manually locking the ST joint, and in external rotation with arm at side were recorded. The humerus, scapula, and implants were manually segmented on post-operative CTs. Post-operative bony structures were registered to preoperative bony elements. From this registration, a post-operative plan corresponding to the real post-operative implant positioning was generated and the corresponding virtual RoM analysis was recorded. On the post-operative anteroposterior X-rays and 2D-CT coronal planning view, the glenoid horizontal line angle (GH), the metaphyseal horizontal line angle (MH), and the gleno-metaphyseal angle (GMA) were measured to assess the extrinsic glenoid inclination, as well as the relative position of the humeral and glenoid components.
Results
There were some significant differences between virtual and post-operative passive abduction and forward elevation, with (55° and 50°, p < 0.0001) or without ST joint participation (15° and 27°, p < 0.002). For external rotation with arm at side, there was no significant difference between planning (24° ± 26°) and post-operative clinical observation (19° ± 12°) (p = 0.38). For the angle measurements, the GMA was significantly higher (42.8° ± 15.2° vs. 29.1°± 18.2°, p < 0.0001), and the GH angle, significantly lower on the virtual planning (85.2° ± 8.8° vs. 99.5° ± 12.5°, p < 0.0001), while the MH was not different (p = 0.33).
Conclusions
The virtual RoM given by the planning software used in this study differs from the real post-operative passive RoM, except for external rotation. This can be explained by the lack of ST joint and soft tissues simulation. However, in focusing on the virtual GH participation, the simulation looks informative. Some modifications between the glenoid and humerus starting positions before running the motion analysis could be provided for making it more realistic and predictive of the RSA functional results. Level of evidence: III.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CHRU Trousseau Service d'Orthopédie Traumatologie, Faculté de Médecine de Tours, Université de Tours, 1C Avenue de la République, 37170 Tours, France.
- Equipe Reconnaissance de Forme et Analyse de l'Image, Laboratoire d'Informatique Fondamentale et Appliquée de Tours EA6300, Ecole d'Ingénieurs Polytechnique Universitaire de Tours, Université de Tours, 64 Avenue Portali…
- Department of Orthopedic Surgery, Faculty of Medicine, University of Jeddah, Jeddah 23218, Saudi Arabia.
- Centre for Chirurgie des Articulations et du Sport (ARTICS), 24 rue du XXIème Régiment d'Aviation, 54000 Nancy, France.
- Institut Locomoteur et du Sport, Hôpital Pasteur 2, 30 Voie Romaine, 06000 Nice, France.
ORCID-Profile: Julien Berhouet, Ramy Samargandi, Marc-Olivier Gauci
Zitieren
APA
Berhouet, J., Samargandi, R., Favard, L., Turbillon, C., Jacquot, A., & Gauci, M. O. (2023). The Real Post-Operative Range of Motion Differs from the Virtual Pre-Operative Planned Range of Motion in Reverse Shoulder Arthroplasty. Journal of Personalized Medicine, 13(5), 765. https://doi.org/10.3390/jpm13050765
Vancouver
Berhouet J, Samargandi R, Favard L, Turbillon C, Jacquot A, Gauci MO. The Real Post-Operative Range of Motion Differs from the Virtual Pre-Operative Planned Range of Motion in Reverse Shoulder Arthroplasty. Journal of Personalized Medicine. 2023;13(5):765. doi:10.3390/jpm13050765
BibTeX
@article{Berhouet2023,
author = {Berhouet, Julien and Samargandi, Ramy and Favard, Luc and Turbillon, Céline and Jacquot, Adrien and Gauci, Marc-Olivier},
title = {The Real Post-Operative Range of Motion Differs from the Virtual Pre-Operative Planned Range of Motion in Reverse Shoulder Arthroplasty},