Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis
Journal of Personalized Medicine · 07.01.2023 · 13 (1) · 125
DOI: 10.3390/jpm13010125 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of Personalized Medicine, online erschienen am 07.01.2023. Verfasst von Alexandru Diaconu und 3 weiteren Autor:innen. Beteiligte Einrichtung: 3D Lab Denmark, Department of Oral and Maxillofacial Surgery, University Hospital of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark. Die Arbeit wurde bisher 59-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This systematic review aimed to determine the accuracy/stability of patient-specific osteosynthesis (PSI) in orthognathic surgery according to three-dimensional (3D) outcome analysis and in comparison to conventional osteosynthesis and computer-aided designed and manufactured (CAD/CAM) splints or wafers. The PRISMA guidelines were followed and six academic databases and Google Scholar were searched. Records reporting 3D accuracy/stability measurements of bony segments fixated with PSI were included. Of 485 initial records, 21 met the eligibility (566 subjects), nine of which also qualified for a meta-analysis (164 subjects). Six studies had a high risk of bias (29%), and the rest were of low or moderate risk. Procedures comprised either single-piece or segmental Le Fort I and/or mandibular osteotomy and/or genioplasty. A stratified meta-analysis including 115 subjects with single-piece Le Fort I PSI showed that the largest absolute mean deviations were 0.5 mm antero-posteriorly and 0.65° in pitch. PSIs were up to 0.85 mm and 2.35° more accurate than conventional osteosynthesis with CAD/CAM splint or wafer (p < 0.0001). However, the clinical relevance of the improved accuracy has not been shown. The literature on PSI for multi-piece Le Fort I, mandibular osteotomies and genioplasty procedure is characterized by high methodological heterogeneity and a lack of randomized controlled trials. The literature is lacking on the 3D stability of bony segments fixated with PSI.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 3D Lab Denmark, Department of Oral and Maxillofacial Surgery, University Hospital of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark.
- Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark.
- Department of Public Health, Faculty of Health Sciences, University of Southern Denmark, Degnevej 14, 6705 Esbjerg, Denmark.
ORCID-Profile: Michael Boelstoft Holte, Gabriele Berg-Beckhoff
Zitieren
APA
Diaconu, A., Holte, M. B., Berg-Beckhoff, G., & Pinholt, E. M. (2023). Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis. Journal of Personalized Medicine, 13(1), 125. https://doi.org/10.3390/jpm13010125
Vancouver
Diaconu A, Holte MB, Berg-Beckhoff G, Pinholt EM. Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis. Journal of Personalized Medicine. 2023;13(1):125. doi:10.3390/jpm13010125
BibTeX
@article{Diaconu2023,
author = {Diaconu, Alexandru and Holte, Michael Boelstoft and Berg-Beckhoff, Gabriele and Pinholt, Else Marie},
title = {Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis},
journal = {Journal of Personalized Medicine},
year = {2023},
volume = {13},
number = {1},
pages = {125},
doi = {10.3390/jpm13010125}
}
EUVIMED