EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Loop-Mediated Isothermal Amplification (LAMP): Potential Point-of-Care Testing for Vulvovaginal Candidiasis

Meng Li, Xiangyu Jin, Qingyun Jiang, Hongbo Wei iD, Anni Deng, Zeyin Mao, Ying Wang, Zhen Zeng, Yifan Wu, Shuai Liu, Juhyun Kim, Xiaoqian Wang und 7 weitere

Journal of Fungi · 02.12.2023 · 9 (12) · 1159

DOI: 10.3390/jof9121159 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Fungi, online erschienen am 02.12.2023. Verfasst von Meng Li und 18 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Medicine, Tsinghua University, Beijing 100084, China. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Laboratory of Precision Medicine, Tsinghua University, Tsinghua University Chunfeng Fund domestic research Project (405-10001000221).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study is to establish a loop-mediated isothermal amplification (LAMP) method for the rapid detection of vulvovaginal candidiasis (VVC).

Methods

We developed and validated a loop-mediated isothermal amplification (LAMP) method for detecting the most common Candida species associated with VVC, including C. albicans, N. glabratus, C. tropicalis, and C. parapsilosis. We evaluated the specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV), and Kappa value of the LAMP method to detect different Candida species, using the conventional culture method and internal transcribed spacer (ITS) sequencing as gold standards and smear Gram staining and real-time Rolymerase Chain Reaction (PCR) as controls.

Results

A total of 202 cases were enrolled, of which 88 were VVC-positive and 114 were negative. Among the 88 positive patients, the fungal culture and ITS sequencing results showed that 67 cases (76.14%) were associated with C. albicans, 13 (14.77%) with N. glabratus, 5 (5.68%) with C. tropicalis, and 3 (3.41%) with other species. Regarding the overall detection rate, the LAMP method presented sensitivity, specificity, PPV, NPV, and Kappa values of 90.91%, 100%, 100%, 93.4%, and 0.919, respectively. Moreover, the LAMP had a specificity of 100% for C. albicans, N. glabratus, and C. tropicalis, with a sensitivity of 94.03%, 100%, and 80%, respectively. Moreover, the microscopy evaluation had the highest sensitivity, while the real-time PCR was less specific for C. albicans than LAMP. In addition, CHROMagar Candida was inferior to LAMP in detecting non-albicans Candida (NAC) species.

Conclusions

Based on the cost-effective, rapid, and inexpensive characteristics of LAMP, coupled with the high sensitivity and specificity of our VVC-associated Candida detection method, we provided a possibility for the point-of-care testing (POCT) of VVC, especially in developing countries and some laboratories with limited resources.

Schlagwörter

Stichwörter der Autor:innen

female genital tractloop-mediated isothermal amplificationmolecular diagnosispoint-of-care testingvulvovaginal candidiasis

Autor:innen und Institutionen

  • School of Clinical Medicine, Tsinghua University, Beijing 100084, China.
  • Department of Obstetrics and Gynecology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing 102218, China.
  • Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
  • Beijing Institute of Spacecraft System Engineering, China Academy of Space Technology, Beijing 100094, China.

ORCID-Profile: Hongbo Wei

Förderung

  • National Natural Science Foundation of China
  • Key Laboratory of Precision Medicine, Tsinghua University
  • Tsinghua University Chunfeng Fund domestic research Project (405-10001000221)
  • National Natural Science Foundation of China, Key instrument Research and development Project

Zitieren

APA

Li, M., Jin, X., Jiang, Q., Wei, H., Deng, A., Mao, Z., Wang, Y., Zeng, Z., Wu, Y., Liu, S., Kim, J., Wang, X., Liu, Y., Liu, J., Lv, W., Huang, L., Liao, Q., Huang, G., & Zhang, L. (2023). Loop-Mediated Isothermal Amplification (LAMP): Potential Point-of-Care Testing for Vulvovaginal Candidiasis. Journal of Fungi, 9(12), 1159. https://doi.org/10.3390/jof9121159

Vancouver

Li M, Jin X, Jiang Q, Wei H, Deng A, Mao Z, et al. Loop-Mediated Isothermal Amplification (LAMP): Potential Point-of-Care Testing for Vulvovaginal Candidiasis. Journal of Fungi. 2023;9(12):1159. doi:10.3390/jof9121159

BibTeX
@article{Li2023,
  author = {Li, Meng and Jin, Xiangyu and Jiang, Qingyun and Wei, Hongbo and Deng, Anni and Mao, Zeyin and Wang, Ying and Zeng, Zhen and Wu, Yifan and Liu, Shuai and Kim, Juhyun and Wang, Xiaoqian and Liu, Ying and Liu, Jun and Lv, Wenqi and Huang, Leyang and Liao, Qinping and Huang, Guoliang and Zhang, Lei},
  title = {Loop-Mediated Isothermal Amplification (LAMP): Potential Point-of-Care Testing for Vulvovaginal Candidiasis},
  journal = {Journal of Fungi},
  year = {2023},
  volume = {9},
  number = {12},
  pages = {1159},
  doi = {10.3390/jof9121159}
}
Kostenlos starten →