Data-Driven Optimization and Validation of Airtightness Test Duration for Hydrogen-Cooled Generators in Nuclear Power Plants
Journal of Nuclear Engineering · 29.06.2026 · 7 (3) · 44
DOI: 10.3390/jne7030044 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Engineering, online erschienen am 29.06.2026. Verfasst von Tianhong Jing und 9 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Research and Development Program of Zhejiang Province, Zhejiang University.
Abstract (Originalsprache)
The sealing reliability of hydrogen-cooled generator systems in nuclear power plants is directly related to unit safety and outage critical-path optimization. Conventional airtightness pressure-holding tests usually use the 24 h leakage result as the acceptance criterion, but this occupies a long maintenance window. Early pressure and temperature signals are affected by thermal equilibration, environmental disturbances, and gas–oil coupling, making direct early assessment difficult. Based on historical pressure-holding test data from multiple nuclear power plants, this study develops a short-duration auxiliary assessment method. Test records from different plants are converted into a unified equivalent leakage rate, and a standardized dataset is established. A multi-branch framework is then developed, including leakage-trend prediction, local fluctuation identification, and feature-space validation. A conservative review strategy is introduced to support safety-oriented field decision making. The validation results show that the first 12 h monitoring data can support assessment of the 24 h leakage state. No false negatives were observed within the limited validation set. Samples with inconsistent outputs, near-threshold predictions, or abnormal feature-space locations are recommended for extended pressure holding and further review.
Förderung
- Key Research and Development Program of Zhejiang Province
- Zhejiang University
Zitieren
APA
Jing, T., Guo, X., Song, J., Gao, S., Zhu, X., Song, X., Feng, Y., Jia, K., Huang, W., & Zhang, Z. (2026). Data-Driven Optimization and Validation of Airtightness Test Duration for Hydrogen-Cooled Generators in Nuclear Power Plants. Journal of Nuclear Engineering, 7(3), 44. https://doi.org/10.3390/jne7030044
Vancouver
Jing T, Guo X, Song J, Gao S, Zhu X, Song X, et al. Data-Driven Optimization and Validation of Airtightness Test Duration for Hydrogen-Cooled Generators in Nuclear Power Plants. Journal of Nuclear Engineering. 2026;7(3):44. doi:10.3390/jne7030044
BibTeX
@article{Jing2026,
author = {Jing, Tianhong and Guo, Xin and Song, Junjie and Gao, Shunyi and Zhu, Xiangyi and Song, Xiuju and Feng, Yixiong and Jia, Kaili and Huang, Wufeng and Zhang, Zhifeng},
title = {Data-Driven Optimization and Validation of Airtightness Test Duration for Hydrogen-Cooled Generators in Nuclear Power Plants},
journal = {Journal of Nuclear Engineering},
year = {2026},
volume = {7},
number = {3},
pages = {44},
doi = {10.3390/jne7030044}
}
EUVIMED