EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis

Yi Yu, Yicheng Zhang, Lichen Tang, Aimin Wu, Chao Pian, Yanfeng Qin, Hao Wang, Lushan Zhang

Journal of Nuclear Engineering · 21.04.2026 · 7 (2) · 30

DOI: 10.3390/jne7020030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Nuclear Engineering, online erschienen am 21.04.2026. Verfasst von Yi Yu und 7 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The steam generator is a core component of nuclear power plants that facilitates heat exchange between the primary and secondary circuits, directly impacting the overall operation of the plant in terms of safety and reliability. During prolonged operation, the heat transfer tubes of the steam generator are subjected to erosion, corrosion, and cracking due to high-temperature, high-pressure fluid impact and vibration. Existing in-service inspection strategies for heat transfer tubes generally employ fixed intervals and coverage, failing to effectively differentiate the actual risk of tubes in various regions, leading to wasted inspection resources or safety hazards. This paper proposes a dynamic inspection and plugging management strategy based on flow-induced vibration (FIV) analysis, specifically utilizing the flow stability ratio (FSR). By calculating the FSR of heat transfer tubes, the strategy categorizes them into high-risk, medium-risk, and low-risk regions, and dynamically adjusts inspection frequency and coverage based on these risk levels. Theoretical analysis and validation with actual data demonstrate that this strategy can improve inspection efficiency and ensure the safety of the steam generator.

Zitieren

APA

Yu, Y., Zhang, Y., Tang, L., Wu, A., Pian, C., Qin, Y., Wang, H., & Zhang, L. (2026). Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis. Journal of Nuclear Engineering, 7(2), 30. https://doi.org/10.3390/jne7020030

Vancouver

Yu Y, Zhang Y, Tang L, Wu A, Pian C, Qin Y, et al. Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis. Journal of Nuclear Engineering. 2026;7(2):30. doi:10.3390/jne7020030

BibTeX
@article{Yu2026,
  author = {Yu, Yi and Zhang, Yicheng and Tang, Lichen and Wu, Aimin and Pian, Chao and Qin, Yanfeng and Wang, Hao and Zhang, Lushan},
  title = {Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis},
  journal = {Journal of Nuclear Engineering},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {30},
  doi = {10.3390/jne7020030}
}
Kostenlos starten →