Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis
Journal of Nuclear Engineering · 21.04.2026 · 7 (2) · 30
DOI: 10.3390/jne7020030 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Engineering, online erschienen am 21.04.2026. Verfasst von Yi Yu und 7 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The steam generator is a core component of nuclear power plants that facilitates heat exchange between the primary and secondary circuits, directly impacting the overall operation of the plant in terms of safety and reliability. During prolonged operation, the heat transfer tubes of the steam generator are subjected to erosion, corrosion, and cracking due to high-temperature, high-pressure fluid impact and vibration. Existing in-service inspection strategies for heat transfer tubes generally employ fixed intervals and coverage, failing to effectively differentiate the actual risk of tubes in various regions, leading to wasted inspection resources or safety hazards. This paper proposes a dynamic inspection and plugging management strategy based on flow-induced vibration (FIV) analysis, specifically utilizing the flow stability ratio (FSR). By calculating the FSR of heat transfer tubes, the strategy categorizes them into high-risk, medium-risk, and low-risk regions, and dynamically adjusts inspection frequency and coverage based on these risk levels. Theoretical analysis and validation with actual data demonstrate that this strategy can improve inspection efficiency and ensure the safety of the steam generator.
Zitieren
APA
Yu, Y., Zhang, Y., Tang, L., Wu, A., Pian, C., Qin, Y., Wang, H., & Zhang, L. (2026). Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis. Journal of Nuclear Engineering, 7(2), 30. https://doi.org/10.3390/jne7020030
Vancouver
Yu Y, Zhang Y, Tang L, Wu A, Pian C, Qin Y, et al. Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis. Journal of Nuclear Engineering. 2026;7(2):30. doi:10.3390/jne7020030
BibTeX
@article{Yu2026,
author = {Yu, Yi and Zhang, Yicheng and Tang, Lichen and Wu, Aimin and Pian, Chao and Qin, Yanfeng and Wang, Hao and Zhang, Lushan},
title = {Management Strategy for In-Service Inspection of Steam Generator Tubes Based on Flow-Induced Vibration Analysis},
journal = {Journal of Nuclear Engineering},
year = {2026},
volume = {7},
number = {2},
pages = {30},
doi = {10.3390/jne7020030}
}
EUVIMED