Optimization of the LIBS Technique in Air, He, and Ar at Atmospheric Pressure for Hydrogen Isotope Detection on Tungsten Coatings
Journal of Nuclear Engineering · 01.07.2025 · 6 (3) · 22
DOI: 10.3390/jne6030022 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Engineering, online erschienen am 01.07.2025. Verfasst von Salvatore Almaviva und 2 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union via the Euratom Research and Training Programme.
Abstract (Originalsprache)
In current and future fusion devices, detecting hydrogen isotopes, particularly tritium and deuterium, implanted or redeposited on the surface of Plasma-Facing Components (PFCs) will be increasingly important to ensure safe machine operations. The Laser-Induced Breakdown Spectroscopy (LIBS) technique has proven capable of performing this task directly in situ, without handling or removing PFCs, thus limiting analysis times and increasing the machine’s duty cycle. To increase sensitivity and the ability to discriminate between isotopes, LIBS analysis can be performed under different background gases at atmospheric pressure, such as air, He, and Ar. In this work, we present the results obtained on tungsten coatings enriched with deuterium and/or hydrogen as a deuterium–tritium nuclear fuel simulant, measured with the LIBS technique in air, He, and Ar at atmospheric pressure, and discuss the pros and cons of their use. The results obtained demonstrate that both He and Ar can improve the LIBS signal resolution of the hydrogen isotopes compared to air. However, using Ar has the additional advantage that the same procedure can also be used to detect He implanted in PFCs as a product of fusion reactions without any interference. Finally, the LIBS signal in an Ar atmosphere increases in terms of the signal-to-noise ratio (SNR), enabling the use of less energetic laser pulses to improve performance in depth profiling analyses.
Förderung
- European Union via the Euratom Research and Training Programme
Zitieren
APA
Almaviva, S., Baiamonte, L., & Pistilli, M. (2025). Optimization of the LIBS Technique in Air, He, and Ar at Atmospheric Pressure for Hydrogen Isotope Detection on Tungsten Coatings. Journal of Nuclear Engineering, 6(3), 22. https://doi.org/10.3390/jne6030022
Vancouver
Almaviva S, Baiamonte L, Pistilli M. Optimization of the LIBS Technique in Air, He, and Ar at Atmospheric Pressure for Hydrogen Isotope Detection on Tungsten Coatings. Journal of Nuclear Engineering. 2025;6(3):22. doi:10.3390/jne6030022
BibTeX
@article{Almaviva2025,
author = {Almaviva, Salvatore and Baiamonte, Lidia and Pistilli, Marco},
title = {Optimization of the LIBS Technique in Air, He, and Ar at Atmospheric Pressure for Hydrogen Isotope Detection on Tungsten Coatings},
journal = {Journal of Nuclear Engineering},
year = {2025},
volume = {6},
number = {3},
pages = {22},
doi = {10.3390/jne6030022}
}
EUVIMED