The Suppression of Flow-Induced Vibrations for a Single and Two Tandem-Arrangement Cylinders Using Three Splitter Plates
Journal of Marine Science and Engineering · 28.08.2024 · 12 (9) · 1487
DOI: 10.3390/jmse12091487 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Marine Science and Engineering, online erschienen am 28.08.2024. Verfasst von Zhongming Hu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key scientific research project of Henan Province, Science and Technology Project of Henan Province.
Abstract (Originalsprache)
Some very useful methods for suppressing the flow-induced vibration (FIV) of a single cylinder are known to potentially have a limited efficiency for tandem-arrangement cylinders. In this paper, three splitter plates uniformly attached around a cylinder with an angle of 120° are proposed to suppress the FIVs of both a single cylinder and two tandem-arrangement cylinders in a wind tunnel at Re = 4000–45,200. The splitter plates’ length to diameter ratios, L/Ds (where L is the length of the splitter plate and D is the cylinder diameter), are set from 0.1 to 0.8. The results show that the proposed method not only effectively suppresses the vortex-induced vibration (VIV) for a single cylinder, but also successfully mitigates the wake-induced galloping (WIG) for two tandem-arrangement cylinders. The vibrations of the single cylinders are effectively suppressed, consistently achieving suppression efficiencies over 95% for L/Ds = 0.2–0.8, with a notable peak efficiency of 98.4% at L/D = 0.2. For the two tandem-arrangement cylinders at S/D = 4.0 (where S is the center-to-center spacing between the two cylinders), the suppression efficiencies of the upstream cylinder exceed 96% for L/D = 0.2–0.8, with an optimal efficiency of 97.4% at L/D = 0.6. The downstream cylinder exhibits vibration only at L/Ds = 0.1, 0.2, and 0.4, resulting in suppression efficiencies of 80.3%, 67.1%, and 91.0%. The vibrations remain fully suppressed throughout the entire reduced velocity range for L/Ds = 0.6–0.8, reaching an optimal efficiency of 98.7% at L/D = 0.6. Three regimes of fs/fn characteristics can be classified for the single cylinder, and the wake structures show that shear layers develop along the front plate before attaching on the cylinder and are then offset to either side of the cylinder by the two rear splitter plates, contributing to the absence of periodic vortex shedding.
Förderung
- National Natural Science Foundation of China
- Key scientific research project of Henan Province
- Science and Technology Project of Henan Province
Zitieren
APA
Hu, Z., Wang, J., Sun, Y., & Lin, K. (2024). The Suppression of Flow-Induced Vibrations for a Single and Two Tandem-Arrangement Cylinders Using Three Splitter Plates. Journal of Marine Science and Engineering, 12(9), 1487. https://doi.org/10.3390/jmse12091487
Vancouver
Hu Z, Wang J, Sun Y, Lin K. The Suppression of Flow-Induced Vibrations for a Single and Two Tandem-Arrangement Cylinders Using Three Splitter Plates. Journal of Marine Science and Engineering. 2024;12(9):1487. doi:10.3390/jmse12091487
BibTeX
@article{Hu2024,
author = {Hu, Zhongming and Wang, Jiasong and Sun, Yuankun and Lin, Ke},
title = {The Suppression of Flow-Induced Vibrations for a Single and Two Tandem-Arrangement Cylinders Using Three Splitter Plates},
journal = {Journal of Marine Science and Engineering},
year = {2024},
volume = {12},
number = {9},
pages = {1487},
doi = {10.3390/jmse12091487}
}