EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence

Helena Kolarova, Jitka Hanusova, Jan Kavalirek, Martin Halaj, Jiri Tesar

Journal of Imaging · 29.10.2026 · 12 (11) · 540

DOI: 10.3390/jimaging12110540 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging, online erschienen am 29.10.2026. Verfasst von Helena Kolarova und 4 weiteren Autor:innen. Die Arbeit nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EURAMET - European Association of National Metrology Institutes.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Low-field magnetic resonance imaging includes portable and open architectures, but quantitative results remain sensitive to field strength, temperature, environment, system state, acquisition, reconstruction, and model fitting. This methodological review asks what evidence supports claims of repeatability, intermediate precision, reproducibility, qualified reference-linked bias, measurement uncertainty, and use relevance. We conducted a targeted synthesis of empirical low-field reports, quantitative-imaging methods, metrology guidance, and MRI standards using a documented search and explicit source-classification criteria. The resulting framework separates three independent axes: represented precision conditions, strength of reference linkage, and relevance to the intended technical or clinical use. Each claim is linked to an experimental design, statistical estimand, configuration record, uncertainty model, and decision rule. An explicitly synthetic low-field T1 example illustrates design identifiability, precision-based replication planning, mixed-effects analysis, an uncertainty budget, and a guard-banded technical decision; it is not experimental validation. A staged pathway allows laboratories to begin with provenance, constancy, and within-system repeatability before progressing to reference-linked or multicentre studies. Meeting a phantom threshold establishes only the specified technical property under the tested conditions; it does not establish diagnostic utility, clinical benefit, regulatory conformity, or CE marking. The framework is an operational synthesis, not a replacement standard or validated quality score.

Förderung

  • EURAMET - European Association of National Metrology Institutes

Zitieren

APA

Kolarova, H., Hanusova, J., Kavalirek, J., Halaj, M., & Tesar, J. (2026). From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence. Journal of Imaging, 12(11), 540. https://doi.org/10.3390/jimaging12110540

Vancouver

Kolarova H, Hanusova J, Kavalirek J, Halaj M, Tesar J. From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence. Journal of Imaging. 2026;12(11):540. doi:10.3390/jimaging12110540

BibTeX
@article{Kolarova2026,
  author = {Kolarova, Helena and Hanusova, Jitka and Kavalirek, Jan and Halaj, Martin and Tesar, Jiri},
  title = {From Repeatability to Reproducibility in Quantitative Low-Field MRI: A Metrology-Informed Framework for Phantom Evidence},
  journal = {Journal of Imaging},
  year = {2026},
  volume = {12},
  number = {11},
  pages = {540},
  doi = {10.3390/jimaging12110540}
}
Kostenlos starten →