EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Lightweight Conformer-Based Framework for Medical Image Classification

Sreelekshmi Vijayasree, Adithya Krishna, Akarsh S Nair, Alfy Alex, Shyamdev Krishnan Jayakrishnan, Jyothisha J Nair

Journal of Imaging · 30.07.2026 · 12 (8) · 344

DOI: 10.3390/jimaging12080344 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Imaging, online erschienen am 30.07.2026. Verfasst von Sreelekshmi Vijayasree und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science and Engineering, Amrita School of Computing, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam 690525, Kerala, India. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Medical image analysis has undergone transformative progress with the application of deep learning models. However, existing architectures often struggle to effectively balance local feature extraction with global contextual understanding, which is crucial for complex diagnostic tasks such as Retinopathy of Prematurity (ROP) detection. In this study, we present a pretrained lightweight Conformer model tailored for medical image classification. The model integrates convolutional layers for capturing fine-grained spatial features with transformer blocks that capture long-range dependencies, creating a unified architecture capable of robust representation learning. We evaluate the model across multiple benchmark medical imaging datasets, including ROP, BloodMNIST, RetinalMNIST and other MedMNIST benchmark datasets. With 93.61% accuracy on the ROP dataset and 99.12% accuracy on BloodMNIST, experimental results show competitive classification performance while lowering model complexity to 12.4 million parameters and 3.2 GFLOPs. Experimental results demonstrate that the comparative studies versus CNN-based and transformer-based architectures, such as ResNet50, Swin-Tiny, ConvNeXt-Tiny, Vision Transformer, and MedViT. The findings show that in clinical settings with limited resources, the suggested lightweight Conformer offers a practical and computationally efficient alternative for medical image interpretation. Furthermore, the lightweight design ensures computational efficiency, making it suitable for deployment in resource-constrained healthcare environments. These findings validate the lightweight Conformer model’s potential for scalable, accurate, and real-time medical image classification.

Schlagwörter

Stichwörter der Autor:innen

conformer architectureconvolutional neural networksdeep learningdisease diagnosishealthcare technologymedical image classificationmedical informaticspretrained modelsretinopathy of prematuritytransformer networks

Autor:innen und Institutionen

  • Department of Computer Science and Engineering, Amrita School of Computing, Amrita Vishwa Vidyapeetham, Amritapuri, Kollam 690525, Kerala, India.
  • School of Computer Sciences, Mahatma Gandhi University, Kottayam 686001, Kerala, India.

Zitieren

APA

Vijayasree, S., Krishna, A., Nair, A. S., Alex, A., Jayakrishnan, S. K., & Nair, J. J. (2026). A Lightweight Conformer-Based Framework for Medical Image Classification. Journal of Imaging, 12(8), 344. https://doi.org/10.3390/jimaging12080344

Vancouver

Vijayasree S, Krishna A, Nair AS, Alex A, Jayakrishnan SK, Nair JJ. A Lightweight Conformer-Based Framework for Medical Image Classification. Journal of Imaging. 2026;12(8):344. doi:10.3390/jimaging12080344

BibTeX
@article{Vijayasree2026,
  author = {Vijayasree, Sreelekshmi and Krishna, Adithya and Nair, Akarsh S and Alex, Alfy and Jayakrishnan, Shyamdev Krishnan and Nair, Jyothisha J},
  title = {A Lightweight Conformer-Based Framework for Medical Image Classification},
  journal = {Journal of Imaging},
  year = {2026},
  volume = {12},
  number = {8},
  pages = {344},
  doi = {10.3390/jimaging12080344}
}
Kostenlos starten →