Fachartikel in der Zeitschrift Journal of Imaging, online erschienen am 13.06.2026. Verfasst von Emre Kopanoglu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff CF24 4HQ, UK. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institutes of Health, Cardiff University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Excitation using nonlinear gradient magnetic fields is investigated as a means of sub-volume magnetic resonance imaging (MRI). Conventional gradient fields provide encoding along a single direction, whereas nonlinear gradient fields encode information simultaneously along at least two directions. This leads to excitation regions (FOX) that have curvilinear boundaries, which may be more tolerant to aliasing artifacts when the encoded field of view (FOV) is smaller than the FOX. This reduces the complexity of the required radiofrequency (RF) excitation pulses and enables accelerated reduced-FOV imaging with standard slice-selection RF-pulses. We demonstrate the approach using a Z2-harmonic field for cylindrical regions of interest (ROIs) with various radius/height ratios. The minimum-FOV that should be encoded is formulated in terms of ROI and RF pulse parameters to allow a theoretical evaluation of feasibility during study design. The investigated method is compared to one-dimensional and two-dimensional selective RF pulses in terms of echo time, scan time and specific absorption rate (SAR) using simulations and phantom experiments. The investigated method yields lower scan time while keeping the SAR unaltered compared to a conventional slice-selective RF pulse, and is more efficient in terms of SAR, echo time and scan time compared to two-dimensional selective excitation.

Schlagwörter

Stichwörter der Autor:innen

high-order gradient fieldsmulti-dimensional selective excitationnonlinear gradient fieldsradiofrequency pulse designreduced-FOV imaging

Autor:innen und Institutionen

  • Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff CF24 4HQ, UK.
  • Department of Diagnostic Radiology, Yale University, New Haven, CT 06520, USA.
  • National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara 06800, Türkiye.
  • Department of Electrical and Electronics Engineering, Bilkent University, Ankara 06800, Türkiye.
  • Department of Neurosurgery, Yale University, New Haven, CT 06520, USA.
  • Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA.

ORCID-Profile: Emre Kopanoglu

Förderung

  • National Institutes of Health
  • Cardiff University

Zitieren

APA

Kopanoglu, E., Atalar, E., & Constable, R. T. (2026). SAR-Efficient Sub-Volume Imaging Using Nonlinear Gradient Magnetic Fields. Journal of Imaging, 12(6), 261. https://doi.org/10.3390/jimaging12060261

Vancouver

Kopanoglu E, Atalar E, Constable RT. SAR-Efficient Sub-Volume Imaging Using Nonlinear Gradient Magnetic Fields. Journal of Imaging. 2026;12(6):261. doi:10.3390/jimaging12060261

BibTeX
@article{Kopanoglu2026,
  author = {Kopanoglu, Emre and Atalar, Ergin and Constable, R Todd},
  title = {SAR-Efficient Sub-Volume Imaging Using Nonlinear Gradient Magnetic Fields},
  journal = {Journal of Imaging},
  year = {2026},
  volume = {12},
  number = {6},
  pages = {261},
  doi = {10.3390/jimaging12060261}
}
Kostenlos starten →