A TV–BM3D Iterative Algorithm for VMAT-CT Reconstruction
Journal of Imaging · 10.04.2026 · 12 (4) · 166
DOI: 10.3390/jimaging12040166 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Imaging, online erschienen am 10.04.2026. Verfasst von Chia-Lung Chien und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN 38105, USA. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American Cancer Society, Louisiana Board of Regents Proof-of-Concept/Prototyping Initiative Fund, Louisiana State University LIFT2 Fund.
Abstract (Originalsprache)
Volumetric modulated arc therapy-computed tomography (VMAT-CT), which is the CT reconstructed using the portal images collected during VMAT, can potentially be an effective onsite imaging tool. The goal of this study was to propose an iterative reconstruction algorithm that can further improve the image quality of VMAT-CT and reduce the number of failed reconstructions. An iterative algorithm combining total variation (TV) with block-matching and 3D filtering (BM3D) was proposed, addressing the L1-L2 regularization problem using the split Bregman method. We collected portal images from 67 VMAT cases including 50 phantom and 17 real-patient cases. Both Feldkamp–Davis–Kress (FDK) and TV-BM3D iterative algorithms were used to reconstruct VMAT-CT using the collected images. The preprocessing methods developed by our group previously were also used in this study. A total of 48 out of 50 phantom cases and 15 out of 17 real-patient cases were successfully reconstructed using the iterative algorithm together with image preprocessing. In contrast, 39 phantom cases and 8 patient cases could be reconstructed using the original FDK algorithm, and 44 phantom cases and 11 patient cases could be reconstructed using the FDK algorithm together with preprocessing. Compared with the FDK algorithm, the TV-BM3D iterative algorithm significantly improved the image quality of VMAT-CT at all treatment sites. To the best of our knowledge, this study is the first to develop an iterative VMAT-CT reconstruction algorithm. It can be used to reconstruct CT images locally, and is superior to FDK-based algorithms in terms of the success rate and reconstructed image quality. This strongly supports the use of VMAT-CT as a promising imaging tool for treatment monitoring and adaptive radiotherapy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN 38105, USA.
- Department of Experimental Statistics, Louisiana State University, Baton Rouge, LA 70803, USA.
- Department of Radiation Oncology, Baylor College of Medicine, Houston, TX 77030, USA.
- Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803, USA.
ORCID-Profile: Rui Zhang
Förderung
- American Cancer Society
- Louisiana Board of Regents Proof-of-Concept/Prototyping Initiative Fund
- Louisiana State University LIFT2 Fund
- Louisiana State University Faculty Research Grant
- Kenneth R. Hogstrom Superior Graduate Student Scholarship
Zitieren
APA
Chien, C. L., Guo, B., & Zhang, R. (2026). A TV–BM3D Iterative Algorithm for VMAT-CT Reconstruction. Journal of Imaging, 12(4), 166. https://doi.org/10.3390/jimaging12040166
Vancouver
Chien CL, Guo B, Zhang R. A TV–BM3D Iterative Algorithm for VMAT-CT Reconstruction. Journal of Imaging. 2026;12(4):166. doi:10.3390/jimaging12040166
BibTeX
@article{Chien2026,
author = {Chien, Chia-Lung and Guo, Beibei and Zhang, Rui},
title = {A TV–BM3D Iterative Algorithm for VMAT-CT Reconstruction},
journal = {Journal of Imaging},
year = {2026},
volume = {12},
number = {4},
pages = {166},
doi = {10.3390/jimaging12040166}
}