EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Residual Jaw Bone Volume and Five-Year Outcomes of Custom-Made Subperiosteal Implants: A Retrospective Study

Jan Łoginoff iD, Zuzanna Popińska, Agata Majos iD, Marcin Elgalal

Journal of Functional Biomaterials · 22.09.2026 · 17 (10) · 482

DOI: 10.3390/jfb17100482 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 22.09.2026. Verfasst von Jan Łoginoff und 3 weiteren Autor:innen. Beteiligte Einrichtung: II Department of Radiology and Diagnostic Imaging, Central Clinical Hospital, Medical University of Lodz, 251 Pomorska Street, 92-213 Lodz, Poland. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Custom subperiosteal implants represent an alternative for severe jaw atrophy, yet long-term quantitative bone predictors remain limited. This retrospective study aimed to evaluate 5-year implant survival and determine preoperative volumetric bone thresholds using 3D CT segmentation.

Methods

The unit of analysis was individual implant sites in 40 patients (25 maxillae and 15 mandibles). Primary outcomes were 5-year cumulative implant survival (Kaplan–Meier method) and preoperative total jaw bone volume (cm3) measured via standardized 3D segmentation using BrainLab software (version 1.7.0.116). Group comparisons between surviving and failed sites were performed with 95% confidence intervals (CIs).

Results

Overall 5-year Kaplan–Meier implant survival was 77.5% (31/40; 95% CI: 64.6–90.4%). Maxillary sites achieved a survival rate of 80.0% (20/25; 95% CI: 64.3–95.7%), whereas mandibular sites achieved 73.3% (11/15; 95% CI: 51.0–95.6%). Preoperative jaw bone volume was significantly lower in failure cases across both maxillary and mandibular cohorts (p < 0.05). Nine implants failed due to biological (n = 4), mechanical (n = 2), or combined (n = 3) complications.

Conclusions

Residual bone volume exhibits a statistically significant association with framework survival, whereas the categorical Cawood and Howell classification showed no statistically significant association in this cohort. These findings suggest that continuous volumetric assessment may serve as a useful exploratory parameter for surgical risk stratification, though predictive superiority requires validation in larger, adjusted multivariable models.

Schlagwörter

Stichwörter der Autor:innen

alveolar bone losscone-beam computed tomographydental implantsedentulousjawprintingretrospective studiessubperiosteal implantthree-dimensionaltitaniumtreatment outcome

Autor:innen und Institutionen

  • II Department of Radiology and Diagnostic Imaging, Central Clinical Hospital, Medical University of Lodz, 251 Pomorska Street, 92-213 Lodz, Poland.
  • Department of Maxillofacial Surgery, Central Clinical Hospital, Medical University of Lodz, 251 Pomorska Street, 92-213 Lodz, Poland.

ORCID-Profile: Jan Łoginoff, Agata Majos

Zitieren

APA

Łoginoff, J., Popińska, Z., Majos, A., & Elgalal, M. (2026). Residual Jaw Bone Volume and Five-Year Outcomes of Custom-Made Subperiosteal Implants: A Retrospective Study. Journal of Functional Biomaterials, 17(10), 482. https://doi.org/10.3390/jfb17100482

Vancouver

Łoginoff J, Popińska Z, Majos A, Elgalal M. Residual Jaw Bone Volume and Five-Year Outcomes of Custom-Made Subperiosteal Implants: A Retrospective Study. Journal of Functional Biomaterials. 2026;17(10):482. doi:10.3390/jfb17100482

BibTeX
@article{oginoff2026,
  author = {Łoginoff, Jan and Popińska, Zuzanna and Majos, Agata and Elgalal, Marcin},
  title = {Residual Jaw Bone Volume and Five-Year Outcomes of Custom-Made Subperiosteal Implants: A Retrospective Study},
  journal = {Journal of Functional Biomaterials},
  year = {2026},
  volume = {17},
  number = {10},
  pages = {482},
  doi = {10.3390/jfb17100482}
}
Kostenlos starten →