EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Time-Dependent Electrochemical Behavior of PVA/Chitosan Anti-Corrosion Coatings on Biomedical-Grade Steel in Simulated Physiological Conditions

Antonio V Vega iD, Arnold Solano iD, Fausto Acosta-Fiallos iD, Raúl Dávalos Monteiro iD

Journal of Functional Biomaterials · 28.07.2026 · 17 (8) · 363

DOI: 10.3390/jfb17080363 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 28.07.2026. Verfasst von Antonio V Vega und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Biological Sciences and Engineering, Yachay Tech University, Urcuquí 100119, Ecuador. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Yachay Tech.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The corrosion of metallic biomaterials under physiological conditions remains a critical challenge due to the risk of ion release affecting biocompatibility. In this study, the time-dependent electrochemical behavior of a poly(vinyl alcohol) (PVA)/chitosan biopolymer coating applied to biomedical-grade steel was evaluated to assess its protective performance. The coating was prepared via dip-coating using a 9.9:0.1 PVA/chitosan formulation and characterized by FTIR and Raman spectroscopy to confirm intermolecular interactions and film formation. Electrochemical impedance spectroscopy was employed over 216 h of immersion in Hanks’ Balanced Salt Solution to monitor coating degradation and corrosion mechanisms. The coated system exhibited a significant increase in the low-frequency impedance modulus from approximately 1200–1400 to 5000–6000 Ω·cm2, indicating enhanced barrier properties and interfacial stability compared to uncoated steel. Equivalent circuit analysis revealed a transition from a predominantly capacitive, barrier-controlled response at early immersion stages to diffusion-influenced behavior at longer exposure times, associated with electrolyte penetration and interfacial processes. Overall, the PVA/chitosan coating effectively delays corrosion reactions and maintains high impedance under simulated physiological conditions, demonstrating its potential as a protective and biocompatible surface modification for metallic biomedical applications.

Schlagwörter

Stichwörter der Autor:innen

PVA/chitosan coatingsbiomedical steelbiopolymer coatingscorrosion protectiondiffusion mechanismselectrochemical impedance spectroscopyphysiological conditionssurface engineering

Autor:innen und Institutionen

  • School of Biological Sciences and Engineering, Yachay Tech University, Urcuquí 100119, Ecuador.
  • Facultad de Ingeniería en Mecánica y Ciencias de la Producción, Escuela Superior Politécnica del Litoral (ESPOL), Guayaquil 90902, Ecuador.

ORCID-Profile: Antonio V Vega, Arnold Solano, Fausto Acosta-Fiallos, Raúl Dávalos Monteiro

Förderung

  • Universidad Yachay Tech

Zitieren

APA

Vega, A. V., Solano, A., Acosta-Fiallos, F., & Dávalos Monteiro, R. (2026). Time-Dependent Electrochemical Behavior of PVA/Chitosan Anti-Corrosion Coatings on Biomedical-Grade Steel in Simulated Physiological Conditions. Journal of Functional Biomaterials, 17(8), 363. https://doi.org/10.3390/jfb17080363

Vancouver

Vega AV, Solano A, Acosta-Fiallos F, Dávalos Monteiro R. Time-Dependent Electrochemical Behavior of PVA/Chitosan Anti-Corrosion Coatings on Biomedical-Grade Steel in Simulated Physiological Conditions. Journal of Functional Biomaterials. 2026;17(8):363. doi:10.3390/jfb17080363

BibTeX
@article{Vega2026,
  author = {Vega, Antonio V and Solano, Arnold and Acosta-Fiallos, Fausto and Dávalos Monteiro, Raúl},
  title = {Time-Dependent Electrochemical Behavior of PVA/Chitosan Anti-Corrosion Coatings on Biomedical-Grade Steel in Simulated Physiological Conditions},
  journal = {Journal of Functional Biomaterials},
  year = {2026},
  volume = {17},
  number = {8},
  pages = {363},
  doi = {10.3390/jfb17080363}
}
Kostenlos starten →