Acellular Dermal Matrix (WITHderm®) Spacer Grafts for the Prevention of Lower Eyelid Ectropion After Subciliary Approaches in Facial Fracture Surgery: A Preliminary Study
Journal of Functional Biomaterials · 18.04.2026 · 17 (4) · 196
DOI: 10.3390/jfb17040196 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 18.04.2026. Verfasst von Wooseob Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Kangbuk Samsung Hospital, School of Medicine, Sungkyunkwan University, Seoul 03181, Republic of Kor…. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Objectives: The subciliary approach offers excellent exposure for orbital and zygomaticomaxillary complex fracture repair but is associated with a relatively high risk of postoperative lower eyelid ectropion. This study evaluated the preventive efficacy of an acellular dermal matrix (ADM; WITHderm®) spacer graft placed during subciliary incision repair.
Methods
This prospective observational cohort study included 20 patients who underwent open reduction and internal fixation for orbital wall or zygomaticomaxillary complex fractures using a subciliary approach between June and December 2024. A human-derived ADM (WITHderm®) spacer graft was interposed between the orbital septum and the orbicularis oculi muscle during incision closure. Postoperative outcomes were assessed at three time points: ectropion grading at 1 month and scar outcomes at 3 and 6 months using the Patient and Observer Scar Assessment Scale (POSAS).
Results
No patients developed postoperative lower eyelid ectropion at 1-month follow-up (0% incidence). Both patient-reported and observer-reported scar outcomes improved significantly over time. The mean total PSAS score decreased from 21.0 ± 2.85 at 3 months to 11.3 ± 2.13 at 6 months (p < 0.001), while the mean total OSAS score decreased from 21.35 ± 2.25 to 11.4 ± 1.67 (p < 0.001). Overall patient satisfaction and objective scar ratings also showed significant improvement.
Conclusions
ADM (WITHderm®) spacer grafting during subciliary incision repair appears to be a safe and effective strategy for preventing early postoperative lower eyelid ectropion and achieving favorable scar outcomes. Further studies are warranted to confirm these findings.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Kangbuk Samsung Hospital, School of Medicine, Sungkyunkwan University, Seoul 03181, Republic of Korea.
ORCID-Profile: Wooseob Kim, Kyu Nam Kim
Zitieren
APA
Kim, W., Jang, E. A., & Kim, K. N. (2026). Acellular Dermal Matrix (WITHderm®) Spacer Grafts for the Prevention of Lower Eyelid Ectropion After Subciliary Approaches in Facial Fracture Surgery: A Preliminary Study. Journal of Functional Biomaterials, 17(4), 196. https://doi.org/10.3390/jfb17040196
Vancouver
Kim W, Jang EA, Kim KN. Acellular Dermal Matrix (WITHderm®) Spacer Grafts for the Prevention of Lower Eyelid Ectropion After Subciliary Approaches in Facial Fracture Surgery: A Preliminary Study. Journal of Functional Biomaterials. 2026;17(4):196. doi:10.3390/jfb17040196
BibTeX
@article{Kim2026,
author = {Kim, Wooseob and Jang, Eun A and Kim, Kyu Nam},
title = {Acellular Dermal Matrix (WITHderm®) Spacer Grafts for the Prevention of Lower Eyelid Ectropion After Subciliary Approaches in Facial Fracture Surgery: A Preliminary Study},
journal = {Journal of Functional Biomaterials},
year = {2026},
volume = {17},
number = {4},
pages = {196},
doi = {10.3390/jfb17040196}
}
EUVIMED