Physicochemical Characterization of a Strontium Silicate-Based Root Canal Sealer Compared with Two Conventional Sealers
Journal of Functional Biomaterials · 01.04.2026 · 17 (4) · 168
DOI: 10.3390/jfb17040168 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 01.04.2026. Verfasst von Loai Alsofi. Beteiligte Einrichtung: Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Deanship of Scientific Research (DSR) at King Abdulaziz University, Jeddah, Saudi Arabia,, King Abdulaziz University.
Abstract (Originalsprache)
Objectives
To evaluate the physicochemical properties of a novel strontium silicate-based root canal sealer (C-Root SP) in comparison with a calcium silicate-based sealer (TotalFill BC) and an epoxy resin-based sealer (AH Plus).
Methods
Setting time, net mass change (apparent solubility behavior), pH changes, and surface characteristics were assessed based on ISO 6876 and ANSI/ADA Specification No. 57, with minor methodological modifications. Net mass change and pH were evaluated over 28 days. Surface morphology and elemental composition were analyzed after dry and aqueous aging in deionized water using scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy. Data were analyzed using one-way and repeated-measures ANOVA with Tukey’s post hoc test (α = 0.05).
Results
AH Plus exhibited the longest initial and final setting times (10.93 ± 0.65 h and 37.33 ± 0.13 h), whereas TotalFill BC showed the shortest (7.98 ± 0.32 h and 30.18 ± 0.20 h); C-Root SP demonstrated intermediate values (9.35 ± 0.38 h and 32.75 ± 0.57 h) (p < 0.001). C-Root SP exhibited positive net mass change values (indicative of net mass loss), ranging from 5.32 ± 4.72% at 24 h to 6.83 ± 5.55% at 28 days, significantly higher than AH Plus and TotalFill BC (p < 0.001), which showed negative values indicative of apparent mass gain. All sealers demonstrated alkaline conditions, with C-Root SP maintaining the highest apparent pH values throughout the evaluation period (p < 0.001). Surface and compositional changes were observed in the bioceramic sealers following aqueous aging, with increased detectable strontium content in C-Root SP.
Conclusions
C-Root SP exhibited physicochemical behavior consistent with a strontium-modified calcium silicate-based sealer, characterized by hydration-driven hydroxyl ion release resulting in apparent alkalinity and ion exchange-associated behavior, and dynamic surface changes consistent with those reported for bioceramic materials. Clinical Significance: Strontium incorporation may influence hydration-mediated physicochemical behavior; however, further in vitro and in vivo studies are required to determine its clinical relevance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia.
ORCID-Profile: Loai Alsofi
Förderung
- the Deanship of Scientific Research (DSR) at King Abdulaziz University, Jeddah, Saudi Arabia,
- King Abdulaziz University
Zitieren
APA
Alsofi, L. (2026). Physicochemical Characterization of a Strontium Silicate-Based Root Canal Sealer Compared with Two Conventional Sealers. Journal of Functional Biomaterials, 17(4), 168. https://doi.org/10.3390/jfb17040168
Vancouver
Alsofi L. Physicochemical Characterization of a Strontium Silicate-Based Root Canal Sealer Compared with Two Conventional Sealers. Journal of Functional Biomaterials. 2026;17(4):168. doi:10.3390/jfb17040168
BibTeX
@article{Alsofi2026,
author = {Alsofi, Loai},
title = {Physicochemical Characterization of a Strontium Silicate-Based Root Canal Sealer Compared with Two Conventional Sealers},
journal = {Journal of Functional Biomaterials},
year = {2026},
volume = {17},
number = {4},
pages = {168},
doi = {10.3390/jfb17040168}
}