Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction
Journal of Functional Biomaterials · 17.08.2023 · 14 (8) · 429
DOI: 10.3390/jfb14080429 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 17.08.2023. Verfasst von Khaja Moiduddin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Manufacturing Institute, King Saud University, Riyadh 11421, Saudi Arabia. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors extend their appreciation to the Deputyship for Research & Innovation, "Ministry of Education" in Saudi Arabia for funding this research work throu…, Deputyship for Research & Innovation, “Ministry of Education” in Saudi Arabia.
Abstract (Originalsprache)
Three-dimensional (3D) printing, medical imaging, and implant design have all advanced significantly in recent years, and these developments may change how modern craniomaxillofacial surgeons use patient data to create tailored treatments. Polyether-ether-ketone (PEEK) is often seen as an attractive option over metal biomaterials in medical uses, but a solid PEEK implant often leads to poor osseointegration and clinical failure. Therefore, the objective of this study is to demonstrate the quantitative assessment of a custom porous PEEK implant for cranial reconstruction and to evaluate its fitting accuracy. The research proposes an efficient process for designing, fabricating, simulating, and inspecting a customized porous PEEK implant. In this study, a CT scan is utilized in conjunction with a mirrored reconstruction technique to produce a skull implant. In order to foster cell proliferation, the implant is modified into a porous structure. The implant’s strength and stability are examined using finite element analysis. Fused filament fabrication (FFF) is utilized to fabricate the porous PEEK implants, and 3D scanning is used to test its fitting accuracy. The results of the biomechanical analysis indicate that the highest stress observed was approximately 61.92 MPa, which is comparatively low when compared with the yield strength and tensile strength of the material. The implant fitting analysis demonstrates that the implant’s variance from the normal skull is less than 0.4436 mm, which is rather low given the delicate anatomy of the area. The results of the study demonstrate the implant’s endurance while also increasing the patient’s cosmetic value.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Advanced Manufacturing Institute, King Saud University, Riyadh 11421, Saudi Arabia.
- Department of Oral and Maxillofacial Surgery, College of Dentistry and Dental University Hospital, King Saud University Medical City, Riyadh 11545, Saudi Arabia.
- Department of Mechanical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia.
ORCID-Profile: Khaja Moiduddin, Syed Hammad Mian, Sherif Mohammed Elseufy, Hisham Alkhalefah, Sundar Ramalingam, Abdul Sayeed
Förderung
- The authors extend their appreciation to the Deputyship for Research & Innovation, "Ministry of Education" in Saudi Arabia for funding this research work throu…
- Deputyship for Research & Innovation, “Ministry of Education” in Saudi Arabia
Zitieren
APA
Moiduddin, K., Mian, S. H., Elseufy, S. M., Alkhalefah, H., Ramalingam, S., & Sayeed, A. (2023). Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction. Journal of Functional Biomaterials, 14(8), 429. https://doi.org/10.3390/jfb14080429
Vancouver
Moiduddin K, Mian SH, Elseufy SM, Alkhalefah H, Ramalingam S, Sayeed A. Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction. Journal of Functional Biomaterials. 2023;14(8):429. doi:10.3390/jfb14080429
BibTeX
@article{Moiduddin2023,
author = {Moiduddin, Khaja and Mian, Syed Hammad and Elseufy, Sherif Mohammed and Alkhalefah, Hisham and Ramalingam, Sundar and Sayeed, Abdul},
title = {Polyether-Ether-Ketone (PEEK) and Its 3D-Printed Quantitate Assessment in Cranial Reconstruction},
journal = {Journal of Functional Biomaterials},
year = {2023},
volume = {14},
number = {8},
pages = {429},
doi = {10.3390/jfb14080429}
}
EUVIMED