EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

pH-Activated Dissolvable Polymeric Coatings to Reduce Biofouling on Electrochemical Sensors

Ahmet Uçar iD, Eva González-Fernández, Matteo Staderini, Alan F Murray, Andrew R Mount, Mark Bradley

Journal of Functional Biomaterials · 20.06.2023 · 14 (6) · 329

DOI: 10.3390/jfb14060329 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Functional Biomaterials, online erschienen am 20.06.2023. Verfasst von Ahmet Uçar und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, Institute for Bioengineering, The University of Edinburgh, The King's Buildings, Mayfield Road, Edinburgh EH9 3JL, UK. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, EPSRC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Implantable electrochemical sensors that enable the real-time detection of significant biomarkers offer huge potential for the enhancement and personalisation of therapies; however, biofouling is a key challenge encountered by any implantable system. This is particularly an issue immediately after implantation, when the foreign body response and associated biofouling processes are at their most active in passivating a foreign object. Here, we present the development of a sensor protection and activation strategy against biofouling, based on coatings consisting of a pH-triggered, dissolvable polymer, that covered a functionalised electrode surface. We demonstrate that reproducible delayed sensor activation can be achieved, and that the length of this delay can be controlled by the optimisation of coating thickness, homogeneity and density through tuning of the coating method and temperature. Comparative evaluation of the polymer-coated and uncoated probe-modified electrodes in biological media revealed significant improvements in their anti-biofouling characteristics, demonstrating that this offers a promising approach to the design of enhanced sensing devices.

Schlagwörter

Stichwörter der Autor:innen

biofoulingdissolvable packagingelectrochemical sensingimplantable devicespH-activation

Autor:innen und Institutionen

  • School of Engineering, Institute for Bioengineering, The University of Edinburgh, The King's Buildings, Mayfield Road, Edinburgh EH9 3JL, UK.
  • Department of Energy Systems Engineering, Faculty of Engineering and Natural Sciences, Ankara Yıldırım Beyazıt University, 06010 Ankara, Turkey.
  • School of Chemistry, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh EH9 3FJ, UK.

ORCID-Profile: Ahmet Uçar

Förderung

  • Engineering and Physical Sciences Research Council
  • EPSRC

Zitieren

APA

Uçar, A., González-Fernández, E., Staderini, M., Murray, A. F., Mount, A. R., & Bradley, M. (2023). pH-Activated Dissolvable Polymeric Coatings to Reduce Biofouling on Electrochemical Sensors. Journal of Functional Biomaterials, 14(6), 329. https://doi.org/10.3390/jfb14060329

Vancouver

Uçar A, González-Fernández E, Staderini M, Murray AF, Mount AR, Bradley M. pH-Activated Dissolvable Polymeric Coatings to Reduce Biofouling on Electrochemical Sensors. Journal of Functional Biomaterials. 2023;14(6):329. doi:10.3390/jfb14060329

BibTeX
@article{Uar2023,
  author = {Uçar, Ahmet and González-Fernández, Eva and Staderini, Matteo and Murray, Alan F and Mount, Andrew R and Bradley, Mark},
  title = {pH-Activated Dissolvable Polymeric Coatings to Reduce Biofouling on Electrochemical Sensors},
  journal = {Journal of Functional Biomaterials},
  year = {2023},
  volume = {14},
  number = {6},
  pages = {329},
  doi = {10.3390/jfb14060329}
}
Kostenlos starten →