EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multiclass Differentiation of Dementia Subtypes Based on Low-Density EEG Biomarkers: Towards Wearable Brain Health Monitoring

Anneliese Walsh, Shreejith Shanker, Alejandro Lopez Valdes

Journal of Dementia and Alzheimer's Disease · 17.12.2025 · 2 (4) · 48

DOI: 10.3390/jdad2040048 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Dementia and Alzheimer's Disease, online erschienen am 17.12.2025. Verfasst von Anneliese Walsh und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NVIDIA and utilised NVIDIA RTX A5000 GPU.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Wearable EEG devices offer an accessible and unobtrusive system for regular brain health monitoring outside clinical settings. However, due to the current lack of data available from wearable low-density EEG devices, we need to anticipate the extraction of biomarkers for brain health evaluation from available clinical datasets.

Methods

This study evaluates multiclass dementia classification of Alzheimer’s disease, frontotemporal dementia, and healthy controls using features derived from low-density temporal EEG electrodes as a proxy for wearable EEG setups. The feature set comprises power-based metrics, including the 1/f spectral slope, and complexity metrics such as Hjorth parameters and multiscale sample entropy.

Results

Our results show that multiclass differentiation of dementia, using low-density electrode configurations restricted to temporal regions, can achieve results comparable to a full-scalp configuration. Notably, electrode T5, positioned over the left temporo-posterior region, consistently outperformed other configurations, achieving a subject-level accuracy of 83.3% and an F1 score of 82.4%.

Conclusions

These findings highlight the potential of single-site EEG measurement for wearable brain health devices.

Förderung

  • NVIDIA and utilised NVIDIA RTX A5000 GPU

Zitieren

APA

Walsh, A., Shanker, S., & Valdes, A. L. (2025). Multiclass Differentiation of Dementia Subtypes Based on Low-Density EEG Biomarkers: Towards Wearable Brain Health Monitoring. Journal of Dementia and Alzheimer's Disease, 2(4), 48. https://doi.org/10.3390/jdad2040048

Vancouver

Walsh A, Shanker S, Valdes AL. Multiclass Differentiation of Dementia Subtypes Based on Low-Density EEG Biomarkers: Towards Wearable Brain Health Monitoring. Journal of Dementia and Alzheimer's Disease. 2025;2(4):48. doi:10.3390/jdad2040048

BibTeX
@article{Walsh2025,
  author = {Walsh, Anneliese and Shanker, Shreejith and Valdes, Alejandro Lopez},
  title = {Multiclass Differentiation of Dementia Subtypes Based on Low-Density EEG Biomarkers: Towards Wearable Brain Health Monitoring},
  journal = {Journal of Dementia and Alzheimer's Disease},
  year = {2025},
  volume = {2},
  number = {4},
  pages = {48},
  doi = {10.3390/jdad2040048}
}
Kostenlos starten →