Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical & Translational Ophthalmology, online erschienen am 24.03.2026. Verfasst von Ahmad Khatib und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Israel Innovation Authority.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate evaluation of the Near Point of Convergence (NPC) is essential for diagnosing and managing convergence insufficiency (CI). Conventional assessment relies on the patient’s verbal feedback and the examiner’s visual observation, making it subjective and examiner-dependent. The AI-based MobileS platform, previously validated for both diagnosis and home-based therapy of CI, enables smartphone-based measurement and visualisation of NPC through eye tracking, without the need for verbal responses or additional equipment. This study, the third stage of our research programme, examined how ophthalmologists interpret NPC data when presented as videos versus AI-derived graphs.

Methods

Twenty-two ophthalmologists completed an online questionnaire with 20 NPC test cases from the validated MobileS database, presented as both silent videos and AI-derived graphs. Accuracy was analysed using mixed-effects logistic regression, and continuous error was assessed using clustered bootstrap.

Results

Graph-based interpretation showed higher odds of accurate NPC identification than video-based interpretation at the primary ±5 mm threshold (OR = 19.7, 95% CI: 13.50–28.74; p < 0.0001). Absolute error was lower for graphs than videos (Graphs − Videos: −22.73 mm; 95% CI: −26.88 to −18.59; p < 0.0001). “Uncertain” responses occurred in 28.2% of video-based assessments and 0% of graph-based assessments. Off-target errors decreased from 50.2% (videos) to 3.6% (graphs).

Conclusions

AI-derived graphs of eye-movement data were associated with improved NPC estimation, suggesting a potential role in supporting clinical and tele-ophthalmology workflows.

Förderung

  • Israel Innovation Authority

Zitieren

APA

Khatib, A., Jabaly-Habib, H., Raz, S., & Shimshoni, I. (2026). Enhancing Ophthalmologists’ Accuracy in Detecting Convergence Insufficiency Using AI-Derived Graphical Outputs. Journal of Clinical & Translational Ophthalmology, 4(2), 9. https://doi.org/10.3390/jcto4020009

Vancouver

Khatib A, Jabaly-Habib H, Raz S, Shimshoni I. Enhancing Ophthalmologists’ Accuracy in Detecting Convergence Insufficiency Using AI-Derived Graphical Outputs. Journal of Clinical & Translational Ophthalmology. 2026;4(2):9. doi:10.3390/jcto4020009

BibTeX
@article{Khatib2026,
  author = {Khatib, Ahmad and Jabaly-Habib, Haneen and Raz, Shmuel and Shimshoni, Ilan},
  title = {Enhancing Ophthalmologists’ Accuracy in Detecting Convergence Insufficiency Using AI-Derived Graphical Outputs},
  journal = {Journal of Clinical & Translational Ophthalmology},
  year = {2026},
  volume = {4},
  number = {2},
  pages = {9},
  doi = {10.3390/jcto4020009}
}
Kostenlos starten →