EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Filtering Bleb Characteristics in Combined Cataract Surgery with Ex-PRESS Implant vs. Non-Penetrating Deep Sclerectomy. A Prospective, Randomized, Multi-Center Study

Alfonso Anton, Marcos Muñoz, Marta Castany, Alfonso Gil, Alberto Martinez, Francisco Muñoz-Negrete, Jose Urcelay, Javier Moreno-Montañes

Journal of Clinical & Translational Ophthalmology · 2023

DOI: 10.3390/jcto1010004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical & Translational Ophthalmology, 2023. Verfasst von Alfonso Anton und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alcon Laboratories, AJL Ophthalmic, Spanish National Health System.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1)

Background

After filtering surgery, bleb morphology is an indicator of the factors that may determine the final intraocular pressure (IOP). The present study aimed to evaluate and compare filtering bleb characteristics after combined cataract and glaucoma surgery. (2)

Methods

We conducted a prospective multi-center randomized trial. Eyes with glaucoma and cataract were randomly assigned to either phacoemulsification and filtration surgery with an EX-PRESS implant (Alcon) or non-penetrating deep sclerectomy (NPDS) with an ESNOPER implant (AJL). The bleb characteristics were assessed with the Moorfields bleb grading system at months 1 and 12 of follow-up, and the relationship with IOP was analyzed. (3)

Results

There were significant changes in bleb appearance between the assessments at month 1 and month 12. The changes in bleb appearance were more evident in the EX-PRESS group. The central area in the EX-PRESS group decreased from 2.9 at month 1 to 2.4 at month 12 (p = 0.014). Bleb height in the EX-PRESS group decreased from 2.3 at month 1 to 1.8 at month 12 (p = 0.034). The vascularity of the central area in the NPDS group decreased from 1.8 at month 1 to 1.3 at month 12 (p = 0.02). The maximal bleb area was inversely related (r = −0.39; p = 0.03) to the IOP in the NPDS group at month 1. Vascularity in the central area was directly related (r = 0.39; p = 0.01) to a higher IOP in the EX-PRESS group at month 1. Vascularity in the central area (r = 0.56; p < 0.001) and maximal area (r = 0.37; p = 0.012) at month 1 was directly related to a higher IOP in the EX-PRESS group at month 12. (4)

Conclusions

More intense vascularity at month 1 was related to a higher final IOP in the EX-PRESS group. Larger blebs were associated with a lower IOP in the NPDS group.

Förderung

  • Alcon Laboratories
  • AJL Ophthalmic
  • Spanish National Health System

Zitieren

APA

Anton, A., Muñoz, M., Castany, M., Gil, A., Martinez, A., Muñoz-Negrete, F., Urcelay, J., & Moreno-Montañes, J. (2023). Filtering Bleb Characteristics in Combined Cataract Surgery with Ex-PRESS Implant vs. Non-Penetrating Deep Sclerectomy. A Prospective, Randomized, Multi-Center Study. Journal of Clinical & Translational Ophthalmology. https://doi.org/10.3390/jcto1010004

Vancouver

Anton A, Muñoz M, Castany M, Gil A, Martinez A, Muñoz-Negrete F, et al. Filtering Bleb Characteristics in Combined Cataract Surgery with Ex-PRESS Implant vs. Non-Penetrating Deep Sclerectomy. A Prospective, Randomized, Multi-Center Study. Journal of Clinical & Translational Ophthalmology. 2023. doi:10.3390/jcto1010004

BibTeX
@article{Anton2023,
  author = {Anton, Alfonso and Muñoz, Marcos and Castany, Marta and Gil, Alfonso and Martinez, Alberto and Muñoz-Negrete, Francisco and Urcelay, Jose and Moreno-Montañes, Javier},
  title = {Filtering Bleb Characteristics in Combined Cataract Surgery with Ex-PRESS Implant vs. Non-Penetrating Deep Sclerectomy. A Prospective, Randomized, Multi-Center Study},
  journal = {Journal of Clinical & Translational Ophthalmology},
  year = {2023},
  doi = {10.3390/jcto1010004}
}
Kostenlos starten →