EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Punching Shear of FRP-RC Slab–Column Connections: A Comprehensive Database

Yazan Almomani, Roaa Alawadi, Ahmad Tarawneh, Abdullah Alghossoon, Ahmad Aldiabat

Journal of Composites Science · 12.04.2024 · 8 (4) · 145

DOI: 10.3390/jcs8040145 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 12.04.2024. Verfasst von Yazan Almomani und 4 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Several design standards have been developed in the last two decades to estimate the punching capacity of two-way reinforced concrete (RC) slabs reinforced with fiber-reinforced polymer (FRP) reinforcement. FRP-RC design standards include the recently published ACI 440.11-22, CSA/S806-12, and JSCE-2007. These models are either based on empirical data or semi-empirical methods and calibrated using different databases. Additionally, these standards do not have provisions for connections with shear reinforcement. Therefore, a reliable worldwide database for developing and assessing the applicability of such provisions with test results is vital. This study presents a worldwide and up-to-date database for punching shear of FRP-RC slabs. The database includes 197 tested connections, comprising interior and edge connections, with and without shear reinforcement, and a wide range of materials and cross-sectional properties. The database was used to evaluate the accuracy of the mentioned standards in predicting the punching shear capacity. For connections without shear reinforcement, it was determined that the three design standards yielded similar performance with different conservatism levels. ACI 440.11-22 yielded the most conservative results, with average Vexp/Vpred ratios of 2.04 compared to 1.28 and 1.3 for other models. For connection with shear reinforcement, specimens with Evf> 100 GPa resulted in Vexp/Vpred ratios less than 1.0 for ACI and CSA standards.

Zitieren

APA

Almomani, Y., Alawadi, R., Tarawneh, A., Alghossoon, A., & Aldiabat, A. (2024). Punching Shear of FRP-RC Slab–Column Connections: A Comprehensive Database. Journal of Composites Science, 8(4), 145. https://doi.org/10.3390/jcs8040145

Vancouver

Almomani Y, Alawadi R, Tarawneh A, Alghossoon A, Aldiabat A. Punching Shear of FRP-RC Slab–Column Connections: A Comprehensive Database. Journal of Composites Science. 2024;8(4):145. doi:10.3390/jcs8040145

BibTeX
@article{Almomani2024,
  author = {Almomani, Yazan and Alawadi, Roaa and Tarawneh, Ahmad and Alghossoon, Abdullah and Aldiabat, Ahmad},
  title = {Punching Shear of FRP-RC Slab–Column Connections: A Comprehensive Database},
  journal = {Journal of Composites Science},
  year = {2024},
  volume = {8},
  number = {4},
  pages = {145},
  doi = {10.3390/jcs8040145}
}
Kostenlos starten →