EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Tunable Laser-Reduced Graphene Oxide–DNA Aptamer Composite for Rapid Disease Detection

Olga M. Antipova, Mariya I. Trukhanova, Egor A. Danilov, Aleksei V. Shchegolkov, Nina V. Myasishcheva, Ivan I. Bobrinetskiy, Ivan A. Komarov

Journal of Composites Science · 01.11.2026 · 10 (11) · 588

DOI: 10.3390/jcs10110588 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 01.11.2026. Verfasst von Olga M. Antipova und 6 weiteren Autor:innen. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flexible graphene-derived composites are promising transduction materials for rapid biosensing, but conductivity and surface reactivity must be balanced within the same device. Here, a laser-patterned reduced graphene oxide (rGO)/poly(ethylene terephthalate) (PET) composite was developed for label-free resistive detection of herpes simplex virus type 1 (HSV-1) glycoprotein D (gD). A graphene oxide film was spin-coated on PET and locally reduced at 48.3 mJ cm−2 to form conductive contacts and at 25 mJ cm−2 to create a sensing region retaining carboxyl groups. A 5′-amine-modified 44-nucleotide DNA aptamer was covalently immobilized by carbodiimide coupling. Atomic force microscopy indicated a local film thickness of approximately 62–72 nm, while infrared and Raman spectroscopy supported the intended chemical reduction gradient. Aptamer immobilization increased sensor resistance by approximately 5–7%. Across 15 sensors, gD produced a concentration-dependent response that was clearly separated from albumin; a representative endpoint response was approximately 6.5% for gD and 0.7% for albumin. The lowest demonstrated detection level was approximately 100 pM, without a formal statistical LOD calculation. The approximate semilog-linear interval was 1 nM–1 mM, and the response time was 70–100 s. These results demonstrate that spatially programmed laser reduction can integrate conductive and bioreactive functions in a composite-based biosensor on a flexible substrate.

Förderung

  • Russian Science Foundation

Zitieren

APA

Antipova, O. M., Trukhanova, M. I., Danilov, E. A., Shchegolkov, A. V., Myasishcheva, N. V., Bobrinetskiy, I. I., & Komarov, I. A. (2026). Tunable Laser-Reduced Graphene Oxide–DNA Aptamer Composite for Rapid Disease Detection. Journal of Composites Science, 10(11), 588. https://doi.org/10.3390/jcs10110588

Vancouver

Antipova OM, Trukhanova MI, Danilov EA, Shchegolkov AV, Myasishcheva NV, Bobrinetskiy II, et al. Tunable Laser-Reduced Graphene Oxide–DNA Aptamer Composite for Rapid Disease Detection. Journal of Composites Science. 2026;10(11):588. doi:10.3390/jcs10110588

BibTeX
@article{Antipova2026,
  author = {Antipova, Olga M. and Trukhanova, Mariya I. and Danilov, Egor A. and Shchegolkov, Aleksei V. and Myasishcheva, Nina V. and Bobrinetskiy, Ivan I. and Komarov, Ivan A.},
  title = {Tunable Laser-Reduced Graphene Oxide–DNA Aptamer Composite for Rapid Disease Detection},
  journal = {Journal of Composites Science},
  year = {2026},
  volume = {10},
  number = {11},
  pages = {588},
  doi = {10.3390/jcs10110588}
}
Kostenlos starten →