Corrosion Performance of Multiple As-Delivered Steel Reinforcing Bar Types Using the ASTM A955 Rapid Macrocell Test
Journal of Composites Science · 29.10.2026 · 10 (11) · 577
DOI: 10.3390/jcs10110577 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 29.10.2026. Verfasst von Nader Ghafoori und 1 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Concrete Reinforcing Steel Institute.
Abstract (Originalsprache)
Chloride-induced corrosion of steel reinforcement is a major durability concern for reinforced concrete infrastructure exposed to deicing salts and other chloride-bearing environments. The use of corrosion-resistant reinforcing bars provides a potential means of extending structural service life; however, comparative information on the performance of different reinforcement systems under identical exposure conditions remains important for material selection. In this study, bare, quenched and tempered, Duplex 2304 stainless steel, epoxy-coated, galvanized, and ChromX-9100 reinforcing bars were evaluated in the as-received condition using the Rapid Macrocell test described in ASTM A955. Corrosion rate, cumulative corrosion loss, and anode corrosion potential were monitored during the 15-week testing period. The Duplex 2304 stainless steel reinforcing bars exhibited the highest resistance to chloride-induced corrosion, with an overall average corrosion loss of approximately 0.25% of that of the bare reinforcing bars. The epoxy-coated, galvanized, and ChromX-9100 reinforcing bars exhibited overall average corrosion losses of approximately 25%, 33%, and 40% of that of the bare bars, respectively. In contrast, the quenched and tempered reinforcing bars exhibited an overall average corrosion loss approximately 25% greater than that of the bare reinforcement. These findings provide a direct comparative assessment of commonly available reinforcement systems and can assist in evaluating reinforcement options for concrete structures exposed to aggressive chloride environments.
Förderung
- Concrete Reinforcing Steel Institute
Zitieren
APA
Ghafoori, N., & Huynh, B. T. (2026). Corrosion Performance of Multiple As-Delivered Steel Reinforcing Bar Types Using the ASTM A955 Rapid Macrocell Test. Journal of Composites Science, 10(11), 577. https://doi.org/10.3390/jcs10110577
Vancouver
Ghafoori N, Huynh BT. Corrosion Performance of Multiple As-Delivered Steel Reinforcing Bar Types Using the ASTM A955 Rapid Macrocell Test. Journal of Composites Science. 2026;10(11):577. doi:10.3390/jcs10110577
BibTeX
@article{Ghafoori2026,
author = {Ghafoori, Nader and Huynh, Brandon T.},
title = {Corrosion Performance of Multiple As-Delivered Steel Reinforcing Bar Types Using the ASTM A955 Rapid Macrocell Test},
journal = {Journal of Composites Science},
year = {2026},
volume = {10},
number = {11},
pages = {577},
doi = {10.3390/jcs10110577}
}
EUVIMED