Adhesive Evaporation Implication in Dentin Bond Strength and MMP Activation
Journal of Composites Science · 08.08.2026 · 10 (8) · 418
DOI: 10.3390/jcs10080418 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 08.08.2026. Verfasst von Tatjana Maravic und 9 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union.
Abstract (Originalsprache)
(1)
Background
This study aimed to assess how two different adhesive solvent evaporation techniques affect the microtensile bond strength (µTBS) of a universal adhesive to dentin, as well as the enzymatic activity of dentinal matrix metalloproteinases (MMPs) at baseline and after 6-month aging under simulated pulpal pressure. (2)
Methods
Middle-depth dentin surfaces of 32 sound extracted human molars were bonded under simulated pulpal pressure using a universal adhesive (Clearfil Universal Bond Quick) in either etch-and-rinse (ER) or self-etch (SE) mode. Two solvent evaporation approaches were compared: evaporation with a disposable air/water syringe (air) and with a disposable suction device (suction), yielding four experimental groups (n = 8): ER/air, ER/suction, SE/air, and SE/suction. After light-curing for 10 s, a 4 mm composite build-up was created. Specimens were stored in distilled water under simulated pulpal pressure at 37 °C for either 24 h (T0) or 6 months (T6) and then sectioned into sticks and subjected to µTBS testing. Fracture surfaces were examined by scanning electron microscopy (SEM). An additional subset of teeth from each group (n = 3) underwent in situ zymographic analysis, in which bonded sticks were ground and exposed to fluorescein-conjugated gelatin, with enzymatic activity quantified by confocal microscopy. Statistical analysis was performed at a significance threshold of p < 0.05. (3)
Results
Air-drying yielded significantly higher µTBS values than suction drying, irrespective of adhesive application mode (p < 0.05). At T6, SE groups retained bond strength values comparable to baseline (p > 0.05), whereas ER groups showed a significant reduction in bond strength with aging (p < 0.05). The ER mode and suction were associated with significantly increased MMP activity at T0 (p < 0.05), while there were no differences between SE/ER at T6 (p > 0.05), and air increased MMP activity (p < 0.05). (4)
Conclusions
When using an ethanol-based universal adhesive under pulpal pressure, evaporation with a disposable air syringe combined with the self-etch application mode appears to offer greater bonding reliability and stability.
Förderung
- European Union
Zitieren
APA
Maravic, T., Mazzitelli, C., Josic, U., Bai, X., Catani, G., Florenzano, F., Checchi, V., Generali, L., Breschi, L., & Mazzoni, A. (2026). Adhesive Evaporation Implication in Dentin Bond Strength and MMP Activation. Journal of Composites Science, 10(8), 418. https://doi.org/10.3390/jcs10080418
Vancouver
Maravic T, Mazzitelli C, Josic U, Bai X, Catani G, Florenzano F, et al. Adhesive Evaporation Implication in Dentin Bond Strength and MMP Activation. Journal of Composites Science. 2026;10(8):418. doi:10.3390/jcs10080418
BibTeX
@article{Maravic2026,
author = {Maravic, Tatjana and Mazzitelli, Claudia and Josic, Uros and Bai, Xueying and Catani, Giovanni and Florenzano, Federica and Checchi, Vittorio and Generali, Luigi and Breschi, Lorenzo and Mazzoni, Annalisa},
title = {Adhesive Evaporation Implication in Dentin Bond Strength and MMP Activation},
journal = {Journal of Composites Science},
year = {2026},
volume = {10},
number = {8},
pages = {418},
doi = {10.3390/jcs10080418}
}