Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 27.03.2026. Verfasst von Jana Markhoff und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Federal Ministry of Education and Research, German Research Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Degradable polymers, such as poly(L-lactide) (PLLA), are widely investigated for biomedical applications, including drug delivery systems and temporary implants. Their functionality can be expanded by incorporating degradable metal microparticles that may influence degradation behaviour and enable additional surface modification strategies. In this study, the feasibility of composites consisting of PLLA and biodegradable iron microparticles was investigated. Composites were fabricated by solvent casting, providing a gentle alternative to thermal processing methods, which often compromise polymer integrity. Composites were evaluated by thermogravimetric analysis, differential scanning calorimetry, scanning electron microscopy (SEM), tensile testing, dynamic mechanical analysis, and X-ray photoelectron spectroscopy (XPS). Incorporation of iron altered thermal behaviour and crystallinity of PLLA, indicating interactions between polymer matrix and dispersed metal phase that may affect degradation kinetics and material stability. While iron addition reduced Young’s modulus, tensile strength, and elongation at break, composites maintained sufficient structural integrity for potential biomedical applications. XPS and SEM confirmed the embedding of particles within the polymer matrix, enabling potential post-processing approaches. In vitro direct contact and eluate tests demonstrated good cell viability, whereas exposure to free iron particles resulted in dose- and time-dependent cytotoxic effects. Overall, the results demonstrate the feasibility of solvent-cast PLLA–iron composites for resorbable biomedical applications.

Förderung

  • Federal Ministry of Education and Research
  • German Research Foundation

Zitieren

APA

Markhoff, J., Wiechmann, P., Schultz, S., Lebahn, K., Senz, V., Grabow, N., Kessler, O., & Eickner, T. (2026). Feasibility of Solvent-Cast PLLA/Iron Composites for Biomedical Applications. Journal of Composites Science, 10(4), 179. https://doi.org/10.3390/jcs10040179

Vancouver

Markhoff J, Wiechmann P, Schultz S, Lebahn K, Senz V, Grabow N, et al. Feasibility of Solvent-Cast PLLA/Iron Composites for Biomedical Applications. Journal of Composites Science. 2026;10(4):179. doi:10.3390/jcs10040179

BibTeX
@article{Markhoff2026,
  author = {Markhoff, Jana and Wiechmann, Philipp and Schultz, Selina and Lebahn, Kerstin and Senz, Volkmar and Grabow, Niels and Kessler, Olaf and Eickner, Thomas},
  title = {Feasibility of Solvent-Cast PLLA/Iron Composites for Biomedical Applications},
  journal = {Journal of Composites Science},
  year = {2026},
  volume = {10},
  number = {4},
  pages = {179},
  doi = {10.3390/jcs10040179}
}
Kostenlos starten →