Bond–Slip Performance of GFRP Rebars in Concrete Under Alkaline and Thermal Conditioning
Journal of Composites Science · 28.02.2026 · 10 (3) · 131
DOI: 10.3390/jcs10030131 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Composites Science, online erschienen am 28.02.2026. Verfasst von Francesca Nerilli und 3 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This work was partially supported by the Italian Civil Protection Department..
Abstract (Originalsprache)
This study investigates the bond–slip behavior of glass fiber-reinforced polymer (GFRP) bars embedded in concrete and exposed to alkaline environments at different temperatures. Although GFRP reinforcement is increasingly adopted for its corrosion resistance, the long-term bond performance of the bar–concrete interface in high-pH conditions is still not fully understood. To help close this gap, a comprehensive database of 84 pull-out tests from the literature was assembled, focusing on three key parameters: bar surface configuration, exposure duration, and conditioning temperature. The comparative analysis highlights the dominant role of surface treatment in bond degradation and reveals substantial variability across existing results. To complement the literature review, additional pull-out tests were carried out on sand-coated GFRP bars conditioned in an alkaline solution (pH = 12) for 1.5 months at ambient temperature and at 60 °C. These tests showed average reductions in bond strength of approximately 28% and 32%, respectively, compared with unconditioned specimens, together with marked changes in the post-peak portion of the bond–slip response. An analytical formulation was also applied, not as a novel bond–slip law but as a consistent mechanical framework to interpret durability-induced degradation effects, to describe the local interface shear stress–slip law, and to assess the resulting stress and slip distributions along the bonded length. Overall, the combined experimental and analytical findings emphasize the need to account for environmentally induced degradation when evaluating durability and defining design criteria for GFRP-reinforced concrete structures.
Förderung
- This work was partially supported by the Italian Civil Protection Department.
Zitieren
APA
Nerilli, F., Ahmadi, H. M., Imperatore, S., & Vairo, G. (2026). Bond–Slip Performance of GFRP Rebars in Concrete Under Alkaline and Thermal Conditioning. Journal of Composites Science, 10(3), 131. https://doi.org/10.3390/jcs10030131
Vancouver
Nerilli F, Ahmadi HM, Imperatore S, Vairo G. Bond–Slip Performance of GFRP Rebars in Concrete Under Alkaline and Thermal Conditioning. Journal of Composites Science. 2026;10(3):131. doi:10.3390/jcs10030131
BibTeX
@article{Nerilli2026,
author = {Nerilli, Francesca and Ahmadi, Hadi Monsef and Imperatore, Stefania and Vairo, Giuseppe},
title = {Bond–Slip Performance of GFRP Rebars in Concrete Under Alkaline and Thermal Conditioning},
journal = {Journal of Composites Science},
year = {2026},
volume = {10},
number = {3},
pages = {131},
doi = {10.3390/jcs10030131}
}
EUVIMED