Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study
Journal of Clinical Medicine · 17.11.2026 · 15 (22) · 8998
DOI: 10.3390/jcm15228998 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 17.11.2026. Verfasst von Marta Aleksandra Kwiatkowska und 3 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Otologic surgery imposes prolonged static postures and fine-motor demands on the surgeon, yet the ergonomic effect of robotic endoscope holding is unknown. We compared surgeon-perceived workload, fatigue and workflow during microscopic, conventional endoscopic and RobOtol®-assisted endoscopic ear surgery.
Methods
In this prospective single-center pilot study, one surgeon performed 29 procedures: RobOtol® (n = 9), conventional endoscopy (n = 10) and microscopy (n = 10). After each procedure, the surgeon rated five NASA Task Load Index (NASA-TLX)-derived workload domains (0–10; unweighted mean), comfort, neck, eye and hand fatigue, instrument stability and movement precision. Setup time, operative time and repositionings were recorded. Kruskal–Wallis and Holm-adjusted Mann–Whitney U tests were used, with false discovery rate control across secondary outcomes. Rapid Upper Limb Assessment (RULA) scores from intraoperative photographs were analyzed descriptively.
Results
Modified NASA-TLX scores were 3.58 ± 1.50 (RobOtol®), 3.78 ± 1.54 (endoscopy) and 5.52 ± 1.54 (microscopy) (p = 0.026, ε2 = 0.26); no pairwise difference remained significant after Holm adjustment. Eye fatigue was higher with microscopy than with either endoscopic approach (adjusted p ≤ 0.016). Compared with conventional endoscopy, RobOtol® yielded higher surgeon-rated instrument stability (mean difference 2.72, 95% CI 1.79–3.65; adjusted p < 0.001) and movement precision (1.04, 95% CI 0.41–1.67; adjusted p = 0.019) without higher workload. Operative time was longest with microscopy (130.7 vs 76.8 and 77.3 min; p = 0.004). Mean RULA scores were 3.38–3.77 (action level 2) in all groups.
Conclusions
Endoscopic approaches were associated with lower perceived workload and eye fatigue than microscopy, and robotic endoscope holding was associated with higher perceived stability and precision without added workload. As case mix differed between groups and outcomes were self-rated, these hypothesis-generating findings require confirmation in larger multi-surgeon studies with objective performance and posture measurement.
Zitieren
APA
Kwiatkowska, M. A., Dobrowolska, D., Skrzypiec, Ł., & Jurkiewicz, D. (2026). Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study. Journal of Clinical Medicine, 15(22), 8998. https://doi.org/10.3390/jcm15228998
Vancouver
Kwiatkowska MA, Dobrowolska D, Skrzypiec Ł, Jurkiewicz D. Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study. Journal of Clinical Medicine. 2026;15(22):8998. doi:10.3390/jcm15228998
BibTeX
@article{Kwiatkowska2026,
author = {Kwiatkowska, Marta Aleksandra and Dobrowolska, Dominika and Skrzypiec, Łukasz and Jurkiewicz, Dariusz},
title = {Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {22},
pages = {8998},
doi = {10.3390/jcm15228998}
}