EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

Accuracy of Artificial Intelligence-Based Models in Predicting Postoperative Soft Tissue Outcomes Following Orthognathic Surgery: A Systematic Review and Meta-Analysis

Genauigkeit KI-basierter Modelle zur Vorhersage postoperativer Weichteilergebnisse nach orthognather Chirurgie: systematische Übersicht und Metaanalyse

Fawaz Alotaibi, Bader Fatani

Journal of Clinical Medicine · 11.11.2026 · 15 (22) · 8817

DOI: 10.3390/jcm15228817 ↗

Auf einen Blick

12 Studien zeigen für KI-Modelle mittlere Oberflächenfehler von etwa 1 mm, mit den größten Fehlern am Kinn. Zwei kleine unabhängige Vergleiche fielen zugunsten von KI aus.

Fragestellung

Wie genau sagen KI-basierte Modelle postoperative Gesicht-Weichteilveränderungen nach orthognather Chirurgie vorher, und wie schneiden sie im Vergleich zu konventionellen Methoden ab?

Methode

Systematische Übersicht und Metaanalyse; Suche in MEDLINE (PubMed), Scopus, IEEE Xplore, arXiv und Europe PMC bis 23. Oktober 2026; Bewertung mit PROBAST + AI und GRADE.

Ergebnisse

12 Studien (16 Berichte). 3D-Oberflächenfehler: 1,10 mm (95 %-KI 0,72–1,49; 95 %-Prädiktionsintervall 0,04–2,17) in 6 unabhängigen Kohorten mit 152 Patient:innen. Kinn: 1,37 mm (95 %-KI 1,01–1,74).

Einschränkungen

9 von 12 Studien mit hohem Verzerrungsrisiko; 8 nutzten die erreichte statt die geplante Bewegung; 1 Studie extern validiert; Evidenz sehr gering.

Schlussfolgerung der Autor:innen

Nach retrospektiven Auswertungen sagten KI-Modelle die postoperative Gesichtoberfläche mit mittleren Fehlern von etwa 1 mm voraus, meist auf Basis der erreichten Knochenbewegung. Extern validierte, planbasierte Studien sind nötig.

Kernaussagen

  • Mittlere 3D-Oberflächenfehler lagen bei etwa 1 mm.
  • Die größten Fehler traten am Kinn auf.
  • KI war in 2 Vergleichen um 0,2 bis 0,3 mm genauer als Finite-Elemente-Modelle.

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Clinical Medicine, online erschienen am 11.11.2026. Verfasst von Fawaz Alotaibi und 1 weiteren Autor:innen. Die Arbeit nennt 95 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Predicting postoperative facial soft tissue change supports planning and patient counselling in orthognathic surgery. The geometric accuracy of artificial intelligence (AI)-based models has not previously been pooled. This review estimated it and compared the models with conventional methods.

Methods

MEDLINE (PubMed), Scopus, IEEE Xplore, arXiv and the Europe PMC preprint index (which covers medRxiv) were searched to 23 October 2026, supplemented by citation tracking (PROSPERO CRD420261536010). Eligible studies compared AI predictions driven by the planned or achieved skeletal movement with the actual postoperative face. Three-dimensional (3D) surface, 3D landmark and two-dimensional (2D) landmark errors were synthesised separately. Cohort-level errors were summarised descriptively; random-effects syntheses, run only when at least three independent cohorts were available and with one evaluation per potentially overlapping cohort, were reported as exploratory because the within-cohort variances could be verified for one cohort only. Risk of bias was assessed with PROBAST + AI and certainty with GRADE.

Results

Twelve studies (16 reports) were included. In six independent cohorts (152 patients), none driven by a confirmed preoperative plan, the cohort mean 3D surface errors ranged from 0.70 to 1.77 mm (median 1.06 mm) under four definitions of the surface distance; the exploratory random-effects estimate, a summary of these heterogeneous error measures and not a directly comparable, clinically validated or universally applicable measure of accuracy, was 1.10 mm (95% confidence interval [CI] 0.72–1.49; 95% prediction interval 0.04–2.17), with intervals that are approximate because the between-patient basis of the within-cohort variances could be verified for one cohort only. The only evaluation driven by a confirmed preoperative plan reported 1.55 mm. Regional errors were lowest at the nose (cohort means 0.55–0.77 mm; exploratory pooled estimate 0.68 mm) and highest at the chin (1.13–1.60 mm; pooled 1.37 mm, 95% CI 1.01–1.74), where about one patient in four exceeded 2 mm in the two studies reporting patient-level proportions. In the two independent same-patient comparisons, the AI model was more accurate than the finite element model by 0.18 mm (95% CI 0.09–0.27) and 0.29 mm (95% CI 0.20–0.37), differences of uncertain clinical importance that do not establish equivalence or non-inferiority; three further, non-independent comparisons gave −0.19, +0.09 and −0.08 mm. Nine of 12 studies were at high risk of bias, eight used the achieved rather than the planned movement, and one was externally validated. Certainty was very low.

Conclusions

In the developers’ retrospective evaluations, mostly driven by the achieved skeletal movement, AI models predicted the postoperative facial surface with cohort mean errors of about 1 mm, largest at the chin; two small independent comparisons favoured AI over biomechanical simulation by 0.2 to 0.3 mm, a difference of uncertain clinical importance. These estimates describe how closely a model reproduces the face after a known skeletal movement, not the accuracy of a prediction made from a surgical plan. Externally validated, plan-driven studies are needed before clinical reliance.

Zitieren

APA

Alotaibi, F., & Fatani, B. (2026). Accuracy of Artificial Intelligence-Based Models in Predicting Postoperative Soft Tissue Outcomes Following Orthognathic Surgery: A Systematic Review and Meta-Analysis. Journal of Clinical Medicine, 15(22), 8817. https://doi.org/10.3390/jcm15228817

Vancouver

Alotaibi F, Fatani B. Accuracy of Artificial Intelligence-Based Models in Predicting Postoperative Soft Tissue Outcomes Following Orthognathic Surgery: A Systematic Review and Meta-Analysis. Journal of Clinical Medicine. 2026;15(22):8817. doi:10.3390/jcm15228817

BibTeX
@article{Alotaibi2026,
  author = {Alotaibi, Fawaz and Fatani, Bader},
  title = {Accuracy of Artificial Intelligence-Based Models in Predicting Postoperative Soft Tissue Outcomes Following Orthognathic Surgery: A Systematic Review and Meta-Analysis},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {22},
  pages = {8817},
  doi = {10.3390/jcm15228817}
}