Effects of Ambulatory Blood Pressure Monitoring During Polysomnography on Sleep Indices and EEG Power
Journal of Clinical Medicine · 09.11.2026 · 15 (21) · 8759
DOI: 10.3390/jcm15218759 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 09.11.2026. Verfasst von Jeonghoon Kim und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute of Information & Communications Technology Planning & Evaluation, Institute of Information & Communications Technology Planning & Evaluation.
Abstract (Originalsprache)
Background/Objectives: Ambulatory blood pressure monitoring (ABPM) may disturb sleep during polysomnography (PSG), and the first-night effect (FNE) can complicate interpretation. We evaluated changes associated with ABPM and FNE across whole nights and individual measurements.
Methods
This secondary analysis included 72 nominally healthy adults in a balanced two-night crossover, with ABPM on one randomly assigned night. Linear mixed-effects models estimated associations with PSG-derived sleep indices, a composite sleep quality index (SQI), and relative electroencephalographic (EEG) power. Analyses of individual measurements summarized EEG changes, sleep-stage transitions, and automated arousal detections. Benjamini–Hochberg false discovery rate (BH-FDR) adjustment was applied within defined analysis families.
Results
FNE and ABPM were associated with lower SQI (β = −0.049 and −0.051, respectively; both BH-adjusted p = 0.028). FNE was associated with altered sleep continuity and architecture, whereas ABPM was associated with higher light-sleep and lower N3-sleep percentages and higher whole-night relative theta power. In the Night 2 paired analysis, relative delta power was lower and relative alpha, beta, and gamma power were higher during ABPM than before ABPM (all BH-adjusted p < 0.01); the theta difference did not reach significance (BH-adjusted p = 0.0632). Of 655 eligible ABPM measurements beginning during sleep, 395 (60.3%) contained at least one arousal detection within the 2 min measurement window.
Conclusions
These detections indicate temporal co-occurrence and do not establish that cuff inflation caused arousal. Concurrent ABPM and study-night order should be considered when interpreting PSG. An adaptation PSG night may be considered when feasible, as may cuffless blood pressure monitoring once its accuracy has been established for the intended setting.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.
- Department of Biomedical Engineering, Hanyang University, Seoul 04763, Republic of Korea.
- Department of Biomedical Engineering, College of Medicine, Hanyang University, Seoul 04763, Republic of Korea.
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University Guri Hospital, Guri 11923, Republic of Korea.
- Department of Neurology, College of Medicine, Hanyang University Seoul Hospital, Seoul 04763, Republic of Korea.
ORCID-Profile: Jeonghoon Kim, Donghun Kang, Jongshill Lee, Junhee Han, Jeyeon Lee, Myung-Kyu Yi, Byung Sik Kim, Hyun-Jin Kim, Jinseok Park, Jeong-Hun Shin, In Young Kim
Förderung
- Institute of Information & Communications Technology Planning & Evaluation
- Institute of Information & Communications Technology Planning & Evaluation
Zitieren
APA
Kim, J., Kang, D., Lee, J., Han, J., Lee, J., Yi, M. K., Kim, B. S., Kim, H. J., Park, J., Shin, J. H., & Kim, I. Y. (2026). Effects of Ambulatory Blood Pressure Monitoring During Polysomnography on Sleep Indices and EEG Power. Journal of Clinical Medicine, 15(21), 8759. https://doi.org/10.3390/jcm15218759
Vancouver
Kim J, Kang D, Lee J, Han J, Lee J, Yi MK, et al. Effects of Ambulatory Blood Pressure Monitoring During Polysomnography on Sleep Indices and EEG Power. Journal of Clinical Medicine. 2026;15(21):8759. doi:10.3390/jcm15218759
BibTeX
@article{Kim2026,
author = {Kim, Jeonghoon and Kang, Donghun and Lee, Jongshill and Han, Junhee and Lee, Jeyeon and Yi, Myung-Kyu and Kim, Byung Sik and Kim, Hyun-Jin and Park, Jinseok and Shin, Jeong-Hun and Kim, In Young},
title = {Effects of Ambulatory Blood Pressure Monitoring During Polysomnography on Sleep Indices and EEG Power},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {21},
pages = {8759},
doi = {10.3390/jcm15218759}
}
EUVIMED