Clinical Performance of a Contemporary Hybrid Surface Implant System—A Prospective Pilot Study
Journal of Clinical Medicine · 07.11.2026 · 15 (21) · 8691
DOI: 10.3390/jcm15218691 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 07.11.2026. Verfasst von Eswar Kandaswamy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontics, School of Dentistry, Louisiana State University Health Sciences Center, New Orleans, LA 70119, USA. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ZimVie Inc. (United States), ZimVie.
Abstract (Originalsprache)
Background/Objectives: Contemporary implant designs incorporating progressive macrogeometry and hybrid surface characteristics are intended to enhance primary stability while supporting favorable peri-implant tissue outcomes. This prospective cohort study evaluated the 2-year clinical, radiographic, prosthetic, and patient-reported outcomes of a contemporary hybrid surface tapered implant system with progressive macrogeometry.
Methods
Thirty participants received 31 implants and were prospectively followed. Twenty-nine participants (30 implants) completed the 2-year follow-up evaluation. The study was prospectively registered at ClinicalTrials.gov (NCT05498662). Treatment protocols, including adjunctive grafting and loading, were selected according to predefined clinical criteria. Outcomes included implant survival and success, implant stability, peri-implant clinical parameters, marginal bone levels, prosthetic complications, and patient-reported satisfaction. Standardized radiographs were obtained longitudinally to assess marginal bone-level changes.
Results
No implant failures were observed during the study period, and implant success was 96.7% at 2 years. Mean probing depths remained stable, measuring 2.91 ± 0.91 mm at 1 year and 2.86 ± 1.21 mm at 2 years. Marginal bone levels also remained stable between prosthesis delivery and the 1-year follow-up (mean change: 0.00; p > 0.05) and showed a small coronal shift between the 1- and 2-year evaluations (mean change: −0.17; p < 0.001). Prosthetic complications occurred in 16% of sites. Patient-reported satisfaction remained high throughout follow-up.
Conclusions
Within the limitations of this small, single-center prospective cohort study, the evaluated implant system demonstrated acceptable clinical, radiographic, and patient-reported outcomes. Larger prospective studies are needed to confirm these findings.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Periodontics, School of Dentistry, Louisiana State University Health Sciences Center, New Orleans, LA 70119, USA.
- Biostatistics and Data Science, School of Public Health, LSU Health-New Orleans, New Orleans, LA 70112, USA.
- Department of Radiology, School of Dentistry, Louisiana State University Health Sciences Center, New Orleans, LA 70119, USA.
ORCID-Profile: Eswar Kandaswamy, Zixin Li, Qingzhao Yu
Förderung
- ZimVie Inc. (United States)
- ZimVie
Zitieren
APA
Kandaswamy, E., Germain, J. S., Li, Z., Yu, Q., Simmons, D., & Frazier, J. J. (2026). Clinical Performance of a Contemporary Hybrid Surface Implant System—A Prospective Pilot Study. Journal of Clinical Medicine, 15(21), 8691. https://doi.org/10.3390/jcm15218691
Vancouver
Kandaswamy E, Germain JS, Li Z, Yu Q, Simmons D, Frazier JJ. Clinical Performance of a Contemporary Hybrid Surface Implant System—A Prospective Pilot Study. Journal of Clinical Medicine. 2026;15(21):8691. doi:10.3390/jcm15218691
BibTeX
@article{Kandaswamy2026,
author = {Kandaswamy, Eswar and Germain, Jeanne St and Li, Zixin and Yu, Qingzhao and Simmons, David and Frazier, John J},
title = {Clinical Performance of a Contemporary Hybrid Surface Implant System—A Prospective Pilot Study},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {21},
pages = {8691},
doi = {10.3390/jcm15218691}
}
EUVIMED