EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY 4.0

The RETRIAD Study: Comparative First-Pass Reperfusion Performance of EmboTrap III, Trevo NXT, and APERIO Stent Retrievers in Acute Large-Vessel Occlusion Stroke: A Single-Center Retrospective Cohort Study

Die RETRIAD-Studie: Vergleich der First-Pass-Reperfusionsleistung von EmboTrap III, Trevo NXT und APERIO-Stent-Retrievern beim akuten Large-Vessel-Occlusion-Schlaganfall: retrospektive Einzelzentrums-Kohortenstudie

Halil İbrahim Akçay iD

Journal of Clinical Medicine · 29.10.2026 · 15 (21) · 8412

DOI: 10.3390/jcm15218412 ↗

Auf einen Blick

In 56 Patient:innen mit akutem Gefäßverschluss zeigte sich kein statistisch nachweisbarer Unterschied im strikten First-Pass-Effect zwischen APERIO, Trevo NXT und EmboTrap III. Die Schätzungen waren unpräzise.

Fragestellung

Unterscheiden sich APERIO, Trevo NXT und EmboTrap III in der First-Pass-Reperfusion bei akutem Large-Vessel-Occlusion-Schlaganfall?

Methode

Explorative, retrospektive Einzelzentrums-Kohortenstudie; 200 gescreente Patient:innen zwischen 1. März 2024 und 1. August 2026; Analyse von 56 Patient:innen nach Ausschlüssen.

Ergebnisse

Strikter FPE: 16/28 (57,1 %) mit APERIO, 9/14 (64,3 %) mit Trevo NXT und 9/14 (64,3 %) mit EmboTrap III; globales exaktes p = 0,879. Gegenüber APERIO betrug die absolute Risikodifferenz jeweils +7,1 Prozentpunkte (95 %-KI −23,2 bis +33,6).

Einschränkungen

40 Patient:innen hatten bei der ersten Analyse kein 90-Tage-Follow-up; kleine Stichprobe, weite Konfidenzintervalle, nicht randomisierte Zuteilung.

Schlussfolgerung der Autor:innen

Es wurde kein statistisch nachweisbarer Unterschied im strikten FPE zwischen den drei device-basierten Behandlungsstrategien gezeigt. Wegen kleiner Stichprobe, weiter Konfidenzintervalle und nicht randomisierter Zuteilung sind keine Aussagen zu Gleichwertigkeit oder Kausalität möglich.

Kernaussagen

  • Strikter FPE: 57,1 %, 64,3 % und 64,3 %
  • Kein statistisch nachweisbarer Unterschied (p = 0,879)
  • Absolute Risikodifferenz vs. APERIO: +7,1 Prozentpunkte

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Kohortenstudie in der Zeitschrift Journal of Clinical Medicine, online erschienen am 29.10.2026. Verfasst von Halil İbrahim Akçay. Beteiligte Einrichtung: Department of Neurology, Faculty of Medicine, Niğde Ömer Halisdemir University, Bor Yolu Üzeri, Central Campus, 51240 Niğde, Türkiye. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Contemporary stent retrievers differ in design, yet direct comparative evidence regarding their first-pass reperfusion performance using a standardized endpoint remains limited. This study compared first-pass reperfusion outcomes among APERIO, Trevo NXT, and EmboTrap III.

Methods

In this exploratory, single-center retrospective cohort study, 200 patients were screened between 1 March 2024 and 1 August 2026. Forty patients had not completed 90-day follow-up at the time of the initial data analysis. An additional 104 patients were excluded because of tandem occlusion (n = 29), recanalization after intravenous thrombolysis before thrombectomy (n = 8), distal vessel occlusion (n = 30), or successful direct aspiration without stent-retriever deployment (n = 37). The final cohort comprised 56 patients treated with first-line combined stent-retriever and aspiration thrombectomy using APERIO (n = 28), Trevo NXT (n = 14), or EmboTrap III (n = 14). The primary endpoint was strict first-pass effect (FPE), defined as first-pass expanded Treatment in Cerebral Ischemia (eTICI) grade 2c–3.

Results

Strict FPE was achieved in 16/28 (57.1%), 9/14 (64.3%), and 9/14 (64.3%) patients, respectively (global exact p = 0.879). Both comparisons with APERIO yielded an absolute risk difference of +7.1 percentage points (95% CI, −23.2 to +33.6). Exploratory adjusted analyses yielded imprecise estimates. Heidelberg-classified symptomatic intracranial hemorrhage occurred in zero, three, and two patients, respectively.

Conclusions

No statistically detectable difference in strict FPE was demonstrated among the three device-based treatment strategies. However, the small sample size, wide confidence intervals, and nonrandomized treatment allocation preclude conclusions regarding device equivalence or causal effects.

Schlagwörter

Stichwörter der Autor:innen

APERIOEmboTrap IIITrevo NXTeTICIfirst-pass effectlarge-vessel occlusionmechanical thrombectomystent retriever

Autor:innen und Institutionen

  • Department of Neurology, Faculty of Medicine, Niğde Ömer Halisdemir University, Bor Yolu Üzeri, Central Campus, 51240 Niğde, Türkiye.
  • Department of Neurology, Niğde Ömer Halisdemir University Training and Research Hospital, Aşağı Kayabaşı Mahallesi, Hastaneler Caddesi, Kumluca Mevkii, 51100 Niğde, Türkiye.

ORCID-Profile: Halil İbrahim Akçay

Zitieren

APA

Akçay, H. İ. (2026). The RETRIAD Study: Comparative First-Pass Reperfusion Performance of EmboTrap III, Trevo NXT, and APERIO Stent Retrievers in Acute Large-Vessel Occlusion Stroke: A Single-Center Retrospective Cohort Study. Journal of Clinical Medicine, 15(21), 8412. https://doi.org/10.3390/jcm15218412

Vancouver

Akçay Hİ. The RETRIAD Study: Comparative First-Pass Reperfusion Performance of EmboTrap III, Trevo NXT, and APERIO Stent Retrievers in Acute Large-Vessel Occlusion Stroke: A Single-Center Retrospective Cohort Study. Journal of Clinical Medicine. 2026;15(21):8412. doi:10.3390/jcm15218412

BibTeX
@article{Akay2026,
  author = {Akçay, Halil İbrahim},
  title = {The RETRIAD Study: Comparative First-Pass Reperfusion Performance of EmboTrap III, Trevo NXT, and APERIO Stent Retrievers in Acute Large-Vessel Occlusion Stroke: A Single-Center Retrospective Cohort Study},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {21},
  pages = {8412},
  doi = {10.3390/jcm15218412}
}
Kostenlos starten →