EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Shear-Wave Elastography for Predicting the Occurrence and Assessing the Severity of Capsular Contracture After Implant-Based Breast Augmentation and Reconstruction: A Review of the Evidence

Shear-Wave-Elastografie zur Vorhersage des Auftretens und zur Beurteilung der Schwere von Kapselkontraktur nach implantatbasierter Brustaugmentation und -rekonstruktion: eine Übersichtsarbeit zur Evidenz

Mihai Iliescu-Glaja iD, Fabiana Simion iD, Andrei Motoc iD, Daciana Grujic iD, Cristi Tarta iD, Dana Stoian iD

Journal of Clinical Medicine · 28.10.2026 · 15 (21) · 8408

DOI: 10.3390/jcm15218408 ↗

Auf einen Blick

Acht Berichte zeigen: Die periprothetische Steifigkeit nahm bei höherer Baker-Klassifikation zu. SWE war nach Rekonstruktion reproduzierbarer als Strain-Elastografie, die Vorhersage einer späteren Kapselkontraktur blieb unbewiesen.

Fragestellung

Kann Shear-Wave-Elastografie das Auftreten und die Schwere einer Kapselkontraktur nach implantatbasierter Brustaugmentation und -rekonstruktion objektiv erfassen?

Methode

Übersicht der Evidenz; Suche in bibliografischen und Verlagsdatenbanken bis September 2026; kritische Bewertung aller Primärberichte zur Ultraschall-Elastografie der periprothetischen Kapsel.

Ergebnisse

8 Berichte (2011–2026; je 2–51 Patient:innen) aus 4 Gruppen. Bei hoher Kapselkontraktur stieg die periprothetische Steifigkeit mit der Baker-Klassifikation. SWE korrelierte stärker mit dem Baker-Score als Strain-Elastografie (r = 0,81 vs. 0,70).

Einschränkungen

Keine externe Validierung der Schwellenwerte (~52 und 82 kPa); diagnostische Genauigkeit nicht ableitbar; keine Studie zeigte, dass frühe SWE spätere Kontraktur vorhersagt.

Schlussfolgerung der Autor:innen

SWE ist eine vielversprechende Ergänzung zur klinischen Beurteilung, aber kein eigenständiges Kriterium für eine Operation; Standardisierung und prospektive Validierungsstudien sind erforderlich.

Kernaussagen

  • Periprothetische Steifigkeit nahm mit höherer Baker-Klassifikation zu.
  • SWE korrelierte nach Rekonstruktion stärker mit dem Baker-Score als Strain-Elastografie.
  • Frühe SWE sagte spätere Kapselkontraktur in keiner Studie voraus.

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 28.10.2026. Verfasst von Mihai Iliescu-Glaja und 5 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral School, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, No. 2, 300041 Timisoara, Romania. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Victor Babes University of Medicine and Pharmacy Timisoara.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Capsular contracture (CC) is the most common long-term complication of implant-based breast augmentation and reconstruction, yet it is still graded by palpation with the Baker classification, whose interobserver reliability is poor. Shear-wave elastography (SWE) quantifies tissue stiffness non-invasively and could assess the periprosthetic capsule objectively. We searched bibliographic and publisher databases up to September 2026 and critically appraised every primary clinical report applying ultrasound elastography to the periprosthetic capsule. Eight reports (2011–2026; 2–51 patients each) from four groups were identified; seven used shear-wave techniques and one compression elastography. Wherever high-grade contracture was represented, periprosthetic stiffness increased with the Baker grade. After reconstruction, SWE was more reproducible than strain elastography and correlated more closely with the Baker score (r = 0.81 versus 0.70). In one comparative study, stiffness almost completely separated Baker III/IV reconstruction breasts from Baker I/II augmentation breasts (area under the curve 0.994), but the groups also differed in indication, age and protocol, so diagnostic accuracy cannot be inferred; neither proposed threshold (~52 and 82 kPa) has been externally validated. Longitudinal studies show early postoperative stiffening that partly normalizes within a year, but none has shown that early SWE predicts subsequent contracture. SWE is a promising adjunct to clinical assessment, not a stand-alone criterion for surgery; standardized acquisition, indication-matched validation and prospective predictive studies are required before clinical adoption.

Schlagwörter

Stichwörter der Autor:innen

Baker classificationbreast augmentationbreast implantbreast reconstructioncapsular contractureperiprosthetic capsuleshear-wave elastographytissue stiffnessultrasound elastography

Autor:innen und Institutionen

  • Doctoral School, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, No. 2, 300041 Timisoara, Romania.
  • Plastic and Reconstructive Surgery Department, Pius Brinzeu Clinical County Emergency Hospital Timisoara, Casa Austria, Liviu Rebreanu Blvd 156, 300723 Timisoara, Romania.
  • Department of Anatomy and Embryology, Faculty of Medicine, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, No. 2, 300041 Timisoara, Romania.
  • Plastic Surgery Department, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, No. 2, 300041 Timisoara, Romania.
  • Center for Advanced Research in Cardiovascular Pathology and Hemostaseology, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, No. 2, 300041 Timisoara, Romania.
  • Researching Future Surgery II Research Center, Department X, Discipline of General Surgery II, Faculty of Medicine, "Victor Babes" University of Medicine and Pharmacy, E. Murgu Square, No. 2, 300041 Timisoara, Romania.

ORCID-Profile: Mihai Iliescu-Glaja, Fabiana Simion, Andrei Motoc, Daciana Grujic, Cristi Tarta, Dana Stoian

Förderung

  • Victor Babes University of Medicine and Pharmacy Timisoara

Zitieren

APA

Iliescu-Glaja, M., Simion, F., Motoc, A., Grujic, D., Tarta, C., & Stoian, D. (2026). Shear-Wave Elastography for Predicting the Occurrence and Assessing the Severity of Capsular Contracture After Implant-Based Breast Augmentation and Reconstruction: A Review of the Evidence. Journal of Clinical Medicine, 15(21), 8408. https://doi.org/10.3390/jcm15218408

Vancouver

Iliescu-Glaja M, Simion F, Motoc A, Grujic D, Tarta C, Stoian D. Shear-Wave Elastography for Predicting the Occurrence and Assessing the Severity of Capsular Contracture After Implant-Based Breast Augmentation and Reconstruction: A Review of the Evidence. Journal of Clinical Medicine. 2026;15(21):8408. doi:10.3390/jcm15218408

BibTeX
@article{IliescuGlaja2026,
  author = {Iliescu-Glaja, Mihai and Simion, Fabiana and Motoc, Andrei and Grujic, Daciana and Tarta, Cristi and Stoian, Dana},
  title = {Shear-Wave Elastography for Predicting the Occurrence and Assessing the Severity of Capsular Contracture After Implant-Based Breast Augmentation and Reconstruction: A Review of the Evidence},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {21},
  pages = {8408},
  doi = {10.3390/jcm15218408}
}
Kostenlos starten →