EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Association of S2 Alar–Iliac Versus S1-Only Fixation with Spinopelvic Mobility and Acetabular Component Orientation in Total Hip Arthroplasty: A Standing–Sitting EOS Study

Assoziation von S2-alar-iliaker versus nur S1-Fixation mit spinopelviner Mobilität und Azetabulumkomponenten-Orientierung bei totaler Hüftarthroplastik: eine stehende-sitzende EOS-Studie

Burak Abay iD, Meric Enercan iD, Azmi Hamzaoglu iD

Journal of Clinical Medicine · 22.10.2026 · 15 (21) · 8210

DOI: 10.3390/jcm15218210 ↗

Auf einen Blick

Bei 60 THA-Patient:innen nach Wirbelsäulenfusion war S2AI mit geringerer spinopelviner Mobilität und stärkerer femoropelviner Reorientierung verbunden als S1-only. Die statische Schalenorientierung war ähnlich.

Fragestellung

Unterscheidet sich bei THA nach adulter Wirbelsäulenfusion die spinopelvine Mobilität, die femoropelvine Reorientierung, die Azetabulumkomponenten-Orientierung und die Hüftfunktion zwischen S2AI- und S1-only-Fixation?

Methode

Retrospektive vergleichende Kohortenstudie mit 60 Patient:innen nach THA und adulter Wirbelsäulenfusion; EOS im Stand und Sitzen nach 1 Jahr, CT postoperativ, HOOS; multivariable Regression.

Ergebnisse

60 Patient:innen; S2AI (n = 30) vs. S1-only (n = 30). Spinopelvine Steifigkeit häufiger mit S2AI (66,7 % vs. 13,3 %; p < 0,001), ΔSS 7,7 ± 4,8° vs. 18,1 ± 7,0°; ΔPFA 68,8 ± 11,7° vs. 58,7 ± 10,8°; HOOS 79 [68–86] vs. 86 [72–92].

Einschränkungen

Residuale Confounding durch die Komplexität des spinalen Konstrukts verhindert einen kausalen Schluss.

Schlussfolgerung der Autor:innen

S2AI-Fixation war mit reduzierter spinopelviner Mobilität und stärkerer femoropelviner Reorientierung bei ähnlicher statischer Schalenorientierung verbunden.

Kernaussagen

  • S2AI: geringere ΔSS als S1-only
  • S2AI: häufigere spinopelvine Steifigkeit
  • Statische Cup-Orientierung ähnlich; HOOS niedriger

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 22.10.2026. Verfasst von Burak Abay und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Demiroglu Bilim University, 34381 Istanbul, Turkey. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

S2 alar–iliac (S2AI) fixation crosses the sacroiliac joint, unlike fixation terminating at S1, and may be associated with reduced spinopelvic mobility in patients undergoing total hip arthroplasty (THA). We compared spinopelvic mobility, femoropelvic reorientation, acetabular component orientation, and hip-specific function between S2AI and S1-only fixation.

Methods

This retrospective comparative cohort study included 60 patients undergoing THA after adult spinal fusion with S2AI (n = 30) or S1-only (n = 30) fixation. Standing and sitting EOS imaging at 1 year assessed changes in sacral slope (ΔSS) and pelvic–femoral angle (ΔPFA). Immediate postoperative CT measured static acetabular component orientation. Hip-specific function was assessed using the Hip Disability and Osteoarthritis Outcome Score (HOOS). Multivariable regression evaluated associations with ΔSS and HOOS.

Results

Spinopelvic stiffness (ΔSS < 10°) was more frequent with S2AI fixation (66.7% vs. 13.3%; p < 0.001). Compared with S1-only fixation, S2AI was associated with lower ΔSS (7.7 ± 4.8° vs. 18.1 ± 7.0°; p < 0.001) and greater ΔPFA (68.8 ± 11.7° vs. 58.7 ± 10.8°; p = 0.001). Static cup orientation was similar. One-year HOOS was lower with S2AI fixation (79 [68–86] vs. 86 [72–92]; p = 0.01), although ΔHOOS did not differ significantly (p = 0.07). After adjustment, S2AI fixation remained associated with lower ΔSS (β = −7.67; p < 0.001), while greater ΔSS was associated with higher HOOS (β = 3.42 per 5°; p = 0.003).

Conclusions

S2AI fixation was associated with reduced spinopelvic mobility and greater femoropelvic reorientation despite similar static cup orientation. Residual confounding by spinal construct complexity precludes causal inference.

Schlagwörter

Stichwörter der Autor:innen

EOS imagingS2 alar–iliac screwacetabular component orientationhip–spine relationshippelvic–femoral anglesacral slopespinopelvic fixationtotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopedics and Traumatology, Demiroglu Bilim University, 34381 Istanbul, Turkey.
  • Scoliosis and Spine Center-Istanbul, Istanbul Florence Nightingale Hospital, 34381 Istanbul, Turkey.

ORCID-Profile: Burak Abay, Meric Enercan, Azmi Hamzaoglu

Zitieren

APA

Abay, B., Enercan, M., & Hamzaoglu, A. (2026). Association of S2 Alar–Iliac Versus S1-Only Fixation with Spinopelvic Mobility and Acetabular Component Orientation in Total Hip Arthroplasty: A Standing–Sitting EOS Study. Journal of Clinical Medicine, 15(21), 8210. https://doi.org/10.3390/jcm15218210

Vancouver

Abay B, Enercan M, Hamzaoglu A. Association of S2 Alar–Iliac Versus S1-Only Fixation with Spinopelvic Mobility and Acetabular Component Orientation in Total Hip Arthroplasty: A Standing–Sitting EOS Study. Journal of Clinical Medicine. 2026;15(21):8210. doi:10.3390/jcm15218210

BibTeX
@article{Abay2026,
  author = {Abay, Burak and Enercan, Meric and Hamzaoglu, Azmi},
  title = {Association of S2 Alar–Iliac Versus S1-Only Fixation with Spinopelvic Mobility and Acetabular Component Orientation in Total Hip Arthroplasty: A Standing–Sitting EOS Study},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {21},
  pages = {8210},
  doi = {10.3390/jcm15218210}
}
Kostenlos starten →