EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wearable Assessment of Dynamic Trunk Sway Reveals Directional Balance Adaptations During Sling-Assisted Walking After Stroke

Begum Yalcin iD, Yiğit Can Gökhan iD, Hülya Şirzai, Güneş Yavuzer, Hande Argunsah

Journal of Clinical Medicine · 05.08.2026 · 15 (15) · 6104

DOI: 10.3390/jcm15156104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 05.08.2026. Verfasst von Begum Yalcin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Graduate School of Natural and Applied Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul 34752, Türki…. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Türkiye Bilimsel ve Teknolojik Araştırma Kurumu, TUBITAK.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Quantitative assessment of dynamic balance remains challenging in clinical practice. Wearable inertial measurement unit (IMU)-based technologies offer an objective and accessible approach for monitoring postural control. This study aimed to develop and preliminarily validate a wearable IMU-based trunk sway monitoring system (SwayTracker) and investigate trunk sway characteristics in stroke patients walking with and without arm sling support.

Methods

A sternum-mounted IMU system was developed to quantify dynamic trunk sway during walking. Fifteen healthy adults and fourteen stroke patients participated. The healthy participants established normative reference values, whereas the stroke patients completed walking trials with and without arm sling support. Trunk sway was quantified using anteroposterior (AP) and mediolateral (ML) deviations and a polar-coordinate-based sway model.

Results

The healthy reference cohort exhibited a mean trunk sway magnitude (radius) of 8.20 ± 3.16°. The stroke patients demonstrated greater sway during unsupported (15.36 ± 5.83°) and sling-assisted walking (15.35 ± 4.59°). Although overall sway magnitude remained unchanged, the mean sway direction shifted from 69.49° to 110.20°, indicating a redistribution of trunk sway from the anterior-right toward the anterior-left quadrant. Forward sway remained the dominant AP component, whereas ML sway shifted from predominantly rightward to leftward with sling use.

Conclusions

SwayTracker provides a feasible method for objective assessment of dynamic trunk sway during walking. The stroke patients exhibited increased sway magnitude and altered directional organization compared with healthy individuals. Arm sling use primarily modified ML postural compensation patterns rather than reducing overall trunk sway, highlighting the potential of wearable trunk sway monitoring for gait and balance assessment in neurological rehabilitation.

Schlagwörter

Stichwörter der Autor:innen

arm slingdynamic balanceneurological rehabilitationpostural controlstroke rehabilitationtrunk sway

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Graduate School of Natural and Applied Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul 34752, Türkiye.
  • Department of Computer Engineering, Faculty of Engineering and Natural Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul 34752, Türkiye.
  • Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Acibadem Mehmet Ali Aydinlar University, Istanbul 34752, Türkiye.
  • Romatem Move Physical Therapy and Rehabilitation Hospital, Istanbul 34640, Türkiye.

ORCID-Profile: Begum Yalcin, Yiğit Can Gökhan

Förderung

  • Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
  • TUBITAK

Zitieren

APA

Yalcin, B., Gökhan, Y. C., Şirzai, H., Yavuzer, G., & Argunsah, H. (2026). Wearable Assessment of Dynamic Trunk Sway Reveals Directional Balance Adaptations During Sling-Assisted Walking After Stroke. Journal of Clinical Medicine, 15(15), 6104. https://doi.org/10.3390/jcm15156104

Vancouver

Yalcin B, Gökhan YC, Şirzai H, Yavuzer G, Argunsah H. Wearable Assessment of Dynamic Trunk Sway Reveals Directional Balance Adaptations During Sling-Assisted Walking After Stroke. Journal of Clinical Medicine. 2026;15(15):6104. doi:10.3390/jcm15156104

BibTeX
@article{Yalcin2026,
  author = {Yalcin, Begum and Gökhan, Yiğit Can and Şirzai, Hülya and Yavuzer, Güneş and Argunsah, Hande},
  title = {Wearable Assessment of Dynamic Trunk Sway Reveals Directional Balance Adaptations During Sling-Assisted Walking After Stroke},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {15},
  pages = {6104},
  doi = {10.3390/jcm15156104}
}
Kostenlos starten →