EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Uterine Position and Diagnostic Accuracy of Transvaginal 2D, 3D, Transrectal and Transabdominal Ultrasonography in the Assessment of Endometrial and Uterine Cavity Abnormalities—A Narrative Review

Małgorzata Satora iD, Julia Ochocka iD, Julia Janowska, Lucja Zaborowska iD, Artur Ludwin iD

Journal of Clinical Medicine · 31.07.2026 · 15 (15) · 5978

DOI: 10.3390/jcm15155978 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Clinical Medicine, online erschienen am 31.07.2026. Verfasst von Małgorzata Satora und 4 weiteren Autor:innen. Beteiligte Einrichtung: 1st Department of Obstetrics and Gynecology, Medical University of Warsaw, 02-015 Warsaw, Poland. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transvaginal ultrasound (TVS) remains the most frequently performed examination in gynecological patients to evaluate the uterine cavity. Visualization of the endometrium may be limited due to certain uterine positions, particularly axial and retroverted orientations. Alternative diagnostic methods, such as transabdominal ultrasound (TAS) and transrectal ultrasound (TRS), may be useful in patients in whom visualization is suboptimal using the TVS. The aim of the study was to analyze the literature regarding the diagnostic performance of TVS, TAS, and TRS in detecting uterine cavity abnormalities in women with various uterine positions. Studies evaluating ultrasound assessment of uterine cavity pathologies with reference to uterine position were included in this review. The available research suggests that uterine position may influence ultrasound visualization. TAS has been shown to demonstrate lower diagnostic reliability in retroverted or axial uteri, particularly in patients with obesity or when focal lesions are present. TRS may provide improved assessment of endometrial thickness in patients with axial uteri compared with TVS. Uterine position may be a factor affecting the accuracy of evaluation of the uterine cavity in ultrasound. Awareness of these limitations and the use of additional imaging modalities may improve diagnostic accuracy in selected patients. Further studies are needed.

Schlagwörter

Stichwörter der Autor:innen

anteverted uterusaxial uterusendometriumretroverteduterusthree-dimensional transvaginal ultrasoundtransabdominal ultrasoundtransrectal ultrasoundtransvaginal ultrasoundtwo-dimensional transvaginal ultrasounduterine position

Autor:innen und Institutionen

  • 1st Department of Obstetrics and Gynecology, Medical University of Warsaw, 02-015 Warsaw, Poland.
  • Doctoral School, Medical University of Warsaw, 02-091 Warsaw, Poland.

ORCID-Profile: Małgorzata Satora, Julia Ochocka, Lucja Zaborowska, Artur Ludwin

Zitieren

APA

Satora, M., Ochocka, J., Janowska, J., Zaborowska, L., & Ludwin, A. (2026). Uterine Position and Diagnostic Accuracy of Transvaginal 2D, 3D, Transrectal and Transabdominal Ultrasonography in the Assessment of Endometrial and Uterine Cavity Abnormalities—A Narrative Review. Journal of Clinical Medicine, 15(15), 5978. https://doi.org/10.3390/jcm15155978

Vancouver

Satora M, Ochocka J, Janowska J, Zaborowska L, Ludwin A. Uterine Position and Diagnostic Accuracy of Transvaginal 2D, 3D, Transrectal and Transabdominal Ultrasonography in the Assessment of Endometrial and Uterine Cavity Abnormalities—A Narrative Review. Journal of Clinical Medicine. 2026;15(15):5978. doi:10.3390/jcm15155978

BibTeX
@article{Satora2026,
  author = {Satora, Małgorzata and Ochocka, Julia and Janowska, Julia and Zaborowska, Lucja and Ludwin, Artur},
  title = {Uterine Position and Diagnostic Accuracy of Transvaginal 2D, 3D, Transrectal and Transabdominal Ultrasonography in the Assessment of Endometrial and Uterine Cavity Abnormalities—A Narrative Review},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {15},
  pages = {5978},
  doi = {10.3390/jcm15155978}
}
Kostenlos starten →