Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 29.07.2026. Verfasst von Asfand Baig Mirza und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Queen's Hospital, Romford, Barking, Havering and Redbridge University Hospitals NHS Trust, Romford RM7 0AG, UK. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Robotic-assisted spinal instrumentation is increasingly used to support implant placement, reduce radiation exposure, and improve operative workflow. However, UK NHS data describing early programme experience across elective and emergency practice remain limited. This study aimed to evaluate the feasibility, safety profile, and early learning curve of robotic-assisted spinal instrumentation in an unselected UK NHS cohort.
Methods
A retrospective, single-centre, single-arm observational cohort study was conducted, including the first 50 consecutive patients treated from programme inception between June 2024 and January 2026. No exclusion criteria were applied, and each record represented one patient and one operation. Missing data were not imputed, and denominators were reported per variable. Learning curve effects were assessed using Spearman correlation and cumulative sum analysis. Wilson 95% confidence intervals were reported for complication rates.
Results
The mean age was 61.9 years; 50% were male; mean body mass index was 29.0; and median Charlson Comorbidity Index was 3. Indications were degenerative disease in 74%, trauma in 24%, and deformity in 2%. Emergency admissions accounted for 18/50 cases. Robot-specific adverse events included abandonment or conversion in 2/50 cases and system malfunction in 1/50. Surgical complications occurred in 7/50 patients. On surgeon-reviewed routine post-operative imaging, no screw malpositions required revision and no durotomies or vascular injuries were recorded; this represents a clinical revision rate rather than a formal radiological measure of screw accuracy, for which blinded Gertzbein–Robbins grading was not performed. Cumulative sum analysis suggested a potential fluoroscopy change point around case 30, with the median fluoroscopy events falling from 151 to 16 thereafter. Emergency cases involved more instrumented levels, longer operative times, and more open surgery than elective cases.
Conclusions
Robotic-assisted spinal instrumentation was feasible across a diverse UK NHS caseload from C1 to S2, with a low observed complication rate. The findings suggest a fluoroscopy learning curve threshold around case 30. Larger comparative studies with formal radiological accuracy assessment are required.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Queen's Hospital, Romford, Barking, Havering and Redbridge University Hospitals NHS Trust, Romford RM7 0AG, UK.
- Barts and The London School of Medicine and Dentistry, London E1 2AD, UK.
- National Hospital for Neurology and Neurosurgery, Queen Square, London WC1N 3BG, UK.
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London SE5 9RS, UK.
ORCID-Profile: Asfand Baig Mirza, Ibrahim Muhyiddin Muhammad, Feras Fayez, Ariadni Georgiannakis, Amisha Vastani, Taofiq Desmond Sanusi
Zitieren
APA
Baig Mirza, A., Rauf, W., Muhammad, I. M., Fayez, F., Georgiannakis, A., Vastani, A., Singh Alg, V., Qureshi, A., Thakur, B., Arvin, B., Sadek, A. R., & Sanusi, T. D. (2026). Robotic-Assisted Spinal Instrumentation from C1 to S1 Experience of a UK Neurosurgical Tertiary Referral Centre. Journal of Clinical Medicine, 15(15), 5905. https://doi.org/10.3390/jcm15155905
Vancouver
Baig Mirza A, Rauf W, Muhammad IM, Fayez F, Georgiannakis A, Vastani A, et al. Robotic-Assisted Spinal Instrumentation from C1 to S1 Experience of a UK Neurosurgical Tertiary Referral Centre. Journal of Clinical Medicine. 2026;15(15):5905. doi:10.3390/jcm15155905
BibTeX
@article{BaigMirza2026,
author = {Baig Mirza, Asfand and Rauf, Wajiha and Muhammad, Ibrahim Muhyiddin and Fayez, Feras and Georgiannakis, Ariadni and Vastani, Amisha and Singh Alg, Varinder and Qureshi, Anjum and Thakur, Bhaskar and Arvin, Babak and Sadek, Ahmed-Ramadan and Sanusi, Taofiq Desmond},
title = {Robotic-Assisted Spinal Instrumentation from C1 to S1 Experience of a UK Neurosurgical Tertiary Referral Centre},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {15},
pages = {5905},
doi = {10.3390/jcm15155905}
}
EUVIMED